9
MAINTENANCE & CARE
WARNING
Before performing any maintenance
on this machine, stop the engine and
disconnect the spark plug wire!
Inspect the engine, tank and hose for
possible fuel leaks, and repair as
necessary and inspect the entire machine
for damage, loose or missing components
or fastenings, and repair as necessary.
EVERY 10 HOURS (MORE FREQUENTLY IN
DUSTY CONDITIONS)
1. Loosen the air cleaner cover retaining
screw, and remove the cover and filer
element.
2. Inspect the element. If the element is
distorted or damaged, replace it with a
new one.
3. Wash the element in clean fuel, and
squeeze or blow dry. Wash the air cleaner
cover in clean fuel, and wipe or blow dry.
4. Install the element and cover, and the
tighten the cover retaining screw.
EVERY 10/15 HOURS
1. Use the spark plug wrench to remove
the spark plug ( turn counter-clockwise to
remove).
2. Clean and adjust the spark plug gap
to 0.6-0.7mm. Replace any damaged or
visibly worn plug with a champion RCJ6Y
or equivalent.
WHEN THE ENGINE STARTS
IMPORTANT
For maximum performance and operating
life, allow the engine to warm-up before
use.
1. Run the engine at idle speed until
operating temperature is reached (2 to 3
minutes).
2. As the engine warms, open the choke
gradually by slowly pushing the choke
control in to the fully retracted position.
3.The unit should now be ready for use.
If the engine does not start, repeat the
appropriate starting procedures for “hot”
or “cold” engine. If the engine still will
not start, follow the “Starting a Flooded
Engine” procedure (below).
WARNING
Incorrect spark plug installation can result
in serious engine damage!
STARTING A FLOODED ENGINE
1. Disconnect the spark plug lead, and use
the spark plug wrench to remove the plug
in a counterclockwise direction.
2. If the spark plug is fouled or is soaked
with fuel, clean or replace the plug as
required.