![LawnMaster LGBQH9200 Safety And Operating Manual Download Page 17](http://html1.mh-extra.com/html/lawnmaster/lgbqh9200/lgbqh9200_safety-and-operating-manual_3972728017.webp)
17
A STEELFORT PRODUCT
2. GENERATOR MAINTENANCE
•
Make certain that the generator is kept clean
and stored properly.
•
Use a damp cloth to clean exterior surfaces of
the generator.
•
Use an compressed air (25 PSI) to clear dirt and
debris from the generator.
•
Inspect all air vents and cooling slots to ensure
that they are clean and unobstructed.
WARNING
•
DO NOT use water to clean the generator. Water
can enter the generator through the cooling
slots and damage the generator windings.
•
DO NOT modify the generator in any way.
•
DO NOT tamper with governed speed.
Generator supplies correct rated frequency and
voltage when running at factory set.
•
Tampering with the factory reset governor will
void your warranty
3. ENGINE MAINTENANCE
3.1 ENGINE OIL
LawnMaster 10W30 Oil (PP01020005) is
recommended. Other viscosities shown in the chart
may be used when the average temperature in your
area is within the indicated range.
OIL MUST BE
PLACED IN ENGINE BEFORE STARTING.
Ambient temperature
Oil capacity (rated):
See Parameters.
3.2 ADDING OIL
WARNING
The engine is not filled with oil at the factory. Any
operation before it has been properly filled with the
recommended type and amount of oil may result in
engine damage and void your warranty.
1.
Place the engine on a level surface.
2.
Remove the oil maintenance cover and oil
dipstick and wipe oil dipstick clean.
3.
Add recommended oil to the upper limit.
CAUTION
Oil level check
Insert the dipstick into filler port and stay at the filler
neck. Do not screw the dipstick into the port, then
remove the dipstick and check the oil level.
4.
Insert the dipstick into its seal position and fix
the oil maintenance cover.
5.
Properly dispose of any used oil at an approved
waste management facility.
3.3 CHANGING OIL
CAUTION
Change the oil when in hot engine state. The oil can
reach up to 140 °C under that condition. Careful
operation should be taken to prevent burns.
Summary of Contents for LGBQH9200