![LawnMaster L10 Instruction Manual Download Page 20](http://html1.mh-extra.com/html/lawnmaster/l10/l10_instruction-manual_3984578020.webp)
20
Error Indicator
Time Setting Indicators
When a time setting is selected, the corresponding indicator will be green continuous.
Time Setting Buttons
Make sure the control panel is unlocked. Press the time setting button to set the working time.
Then press the OK button.
7KHPRZHUZLOOVWDUWDWWKHVDPHWLPHDVWKH¿UVWZRUNLQJVHVVLRQHYHU\GD\
OPERATION
Error Indicator
Status
Off
The mower is in normal operation.
Red, Continuous
Hardware issue.
Yellow, Flashing
The rain sensor is activated.
Yellow, Continuous
The lift sensor, drop sensor, boundary sensor, or bump sensor is
activated.
3
4
5
Battery Indicator
Battery Indicator
Status
Green, Continuous
6XI¿FLHQWSRZHUIRUPRZLQJIXOO\FKDUJHG
Green, Flashing
Charging; battery capacity is more than 40%.
Yellow, Flashing
Charging; battery capacity is less than 40%.
Red, Continuous
Recharge required.
Red, Flashing
The temperature of battery pack is abnormal, or the
electric core fault.
Green and Red, Alternately Flashing
7KHPRZHULVRQWKHEDVHVWDWLRQZKLOHWKH2Q2IIVZLWFK
LVRQWKH³2´2))SRVLWLRQ
2
Switching On/Off
Control Panel (See Fig. 28)
Signal Indicator
Signal Indicator
Status
Off
Signal of boundary wire is normal.
Red, Flashing
Signal lost.
Position
Status
I
on
O
off