13
5. INTERNAL BATTERY GROUNDING
(Applicable Types).
Remove the appearance cover plate. Use
the nut of M6 to connect the battery
grounding wire with cylinder head cover to
make the ground connection of internal
battery.
6. ELECTRICAL DEVICES
Disconnect all electrical devices from the
generator and switch off the AC circuit
breaker before start the engine.
The generator may be hard to start with
electrical devices connected.
The power of connected electrical devices
cannot exceed the generator max power,
specific power see parameter sheet for
reference.
7. GENERATOR GROUNDING
The generator must be properly connected
to an appropriate ground. It helps prevent
electrical shock if a ground fault condition
exists in the generator or in connected
electrical devices, especially when the unit
is equipped with a wheel kit.
Proper grounding also helps dissipate
static electricity, which often builds up in
ungrounded devices.
DANGER
Electrical Shock
Failure to properly ground the generator
can result in electric shock.
A ground terminal has been provided
on the generator. For remote grounding,
connect a length of heavy gauge(4 mm2)
copper wire between the generator ground
terminal and a copper rod driven into the
ground.
Local electrical codes may also require
proper grounding of the unit. We strongly
recommend that you consult with a
qualified electrician for grounding
requirements in your area.
8. STARTING GENERATOR
8.1.
Perform Operating checklist and
remove all loads.
8.2.
Turn the ventilation knob to “ON”
position when engine is running to make
sure the fuel is flowing.
8.3
. Turn the two-in-one switch to the
“RUN” position.