The Front Panel
7
I
NVERT
O
N
/O
FF
This button toggles polarity inversion of all outputs on and off. This affects
both the left and right channels of the
Main Out
and
Monitor Out
signals.
When the invert mode is off, the signal on Pin 2 is in the normal polarity.
When the invert is on, the signal on Pin 2 is inverted. In balanced mode, Pin 3
is the opposite polarity of Pin 2. In unbalanced mode, Pin 3 is grounded.
M
ONO
O
N
/O
FF
This button toggles the signal output to mono when on, and to stereo when
off. This affects both the
Main Out
and
Monitor Out
signals. Loudness
differences between mono and stereo modes vary depending on the degree
of stereo separation of the music.
C
ALIBRATION
When in calibration mode, the
Rotary Knob
provides fine adjustment to both
Main Out
and
Monitor Out
.
The adjustment range is -0.70 dB to +0.70 dB in 0.1 dB increments. While in this mode, the
Numeric Display
indicates the calibration setting.
Calibration is useful to compensate for minor level differences caused by differences in the input impedances
and input signal range tolerances of driven equipment.
I
NPUT
S
ELECT
B
UTTONS
(I
NPUT
1,
I
NPUT
2,
I
NPUT
3)
This group of buttons selects which of the 3 digital stereo inputs is received by the DA converter circuitry.
Each input selection retains an independent Volume setting.
M
AIN
O
UTPUT
E
NABLE
This button enables or mutes the signals to the
Main Out
connectors. When
in mute, the output is hardware grounded.
M
ONITOR
O
UTPUT
E
NABLE
This button enables or mutes the signals to the
Monitor Out
connectors.
When in mute, the output is hardware grounded.
L
EVEL
D
ISPLAY
This 4 digit numeric display indicates the Volume level of the
Monitor Out
signals. The minimum level is
“00.00” at which the signal is muted. The maximum level is “80.00”, which is full scale.
When the unit is in calibration mode, this 4 digit numeric display indicates the output calibration setting,
which ranges from -0.70 dB to +0.70 dB in 0.1 dB increments.
The Lavry Quintessence