![Lavry DA924 Operation Manual Download Page 13](http://html.mh-extra.com/html/lavry/da924/da924_operation-manual_680982013.webp)
Operations Manual DA924
13
P a r t I I I :
S p e c i f i c a t i o n s
Noise
-110dBFS rms, 130dBFS peak spurious response
Distortion
1kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
1kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
10kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
10kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
Sample rate
96kHx, 88.1kHz, 48kHz, 44.1kHz at +/- 150ppm lock range
40-50kHz wide lock mode (varispeed)
Crystal lock™ tracking 1ppm / 15 seconds
Channel separation
-100dBFs at 1KHz
Flatness response
+/- .05dB (10Hz -20KHz)
Phase linearity
2 degrees (10Hz - 20 KHz)
Digital inputs
two AES/EBU, 110 Ohm, transformer isolated
one Consumer, 75 Ohm, transformer isolated
Analog outputs
AES/EBU balanced 22dBuFS into 600 ohms Max
12dBuFS Min
AES/EBU unbalanced 16dBuFS into 600 ohms Max
6dBuFS Min
Consumer outputs 8.5dBuFS into 10k ohms Max
-2.5dBuFS Min
Warm-up and initial calibration 10 minutes maximum
Hardware
19 inch rack mount, 1U high
115V 60Hz or 220V 50Hz, 20 Watts
Options Removable interface for future I/O hardware interface