TROUBLESHOOTING
Before doing any work on the machine, discon-
nect the electricity and water supplies and dis-
charge the pressure. Proceed systematically to
identify faults following the chart below; if you
are still unable to eliminate the problem, call in
the
Authorized After-Sales Service
.
Fault
When switch “ON” the ma
-
chine will not start work
-
ing
Cause
•
Plug not properly inserted
in socket.
•
Electric socket is faulty.
•
The main voltage is insuf-
ficient.
•
The pump is stuck.
•
Gauge of extension lead
not sufficient.
Repair
•
Fit plug in power socket
correctly.
•
Have electrical socket
checked.
•
Have a check made on the
suitability of the mains
system.
•
Turn switch to ON while
keeping nozzle trigger
pressed; if problem per-
sists, contact an author-
ised service centre.
•
Refer to maintenance sec-
tion.
Fault
The motor stops suddenly
Cause
•
Thermic safety switch has
tripped due to the over-
heating.
• Cable extension seems to
be inadequate.
Repair
•
Leave motor to cool for a
few minutes. If the prob-
lem persists, contact an
authorised service centre.
•
Refer to maintenance sec-
tion.
Fault
The pump doesn’t reach
the necessary pressure
Cause
•
Insufficient flow.
•
Water inlet filter is
clogged.
•
Suction/delivery
valves
are clogged or worn out.
•
Pressure regulator valve
set on minimum.
•
The nozzle is worn out.
Repair
• Check that the delivery
rate is 30% higher than the
value stated on the appli-
ance’s technical data plate.
•
Remove and clean the fil-
ter.
• Contact an authorised
service centre.
•
Increase the pressure by
screwing in the pressure
regulator knob.
•
Replace the nozzle.
Fault
Fluctuating pressure
Cause
•
The nozzle is either clogged
or deformed.
•
Suction/delivery
valves
are clogged or worn out.
•
Worn gaskets.
•
Pressure regulator valve
gaskets worn.
•
The filter is dirty.
Repair
•
Dismantle the lance and
clean the nozzle with
the pin provided.
Contact an authorised serv
-
ice centre.
Contact an authorised serv
-
ice centre.
Contact an authorised serv
-
ice centre.
Remove and clean the filter.
Fault
Water leak from appliance
Cause
•
Water leaking from the
pump.
•
Leaks from hose reel (if
present).
•
Leaks from pressure regu-
lator valve.
•
Leaks from water unions.
EN
19
Summary of Contents for DANUBIO LP
Page 49: ...30 cm KL 1 A S S 2 A S S 5 OFF EL 49...
Page 50: ...20 l min 40 C 1Mpa 1 5 10 bar 1 4 13mm IEC 364 0 03 A 30 ms EL 50...
Page 52: ...1 8 17 B A by pass 60 C 2 14 S 1 1 7 7A 7B 10A 10B 10A 10B A EL 52...
Page 53: ...50 500 SAE 20 30 0 5 Kg 21 5 10 92 92 ON EL 53...
Page 54: ...30 EL 54...
Page 55: ...E 2002 96 27 2003 EL 55...
Page 62: ...30 1 A S S 2 A S S stand by 5 OFF RU 62...
Page 63: ...20 40 C 1Mpa 1 5 10 1 4 13 I 364 RU 63...
Page 65: ...1 7 7A 7B 10A 10B kuva 10A 10B 1 8 17 60 2 RU 65...
Page 66: ...14 S 50 500 SAE 20 30 500 21 5 10 7 7 RU 66...
Page 67: ...0 30 RU 67...
Page 68: ...12 2002 96 EC 27 2003 2002 96 EC RU 68...
Page 91: ...91...