NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2017, Lavorwash
Kerosene Forced Air Heater User’s Manual
Operation
Fueling The Heater:
Paraffin
For optimal performance of this heater, it is
strongly suggested that paraffin be used.
paraffin has been refined to virtually eliminate
contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the
heater. Using diesel fuel can cause excess soot
production. Do not use Bio-Diesel as this fuel will
damage your heater’s seals and filter.
- NEVER use fuel such as benzene, alcohol, white
glass, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store paraffin in the living space. Paraffin
should be stored in a well ventilated area outside
the living area.
- NEVER store paraffin in direct sunlight or near a
source of heat.
- NEVER use paraffin that has been stored from one
season to the next. Paraffin deteriorates over time.
OLD Paraffin WILL NOT BURN PROPERLY IN
THIS HEATER.
NOTE: Paraffin should only be stored in a blue
container that is clearly marked “Paraffin.” Never
store paraffin in a red container. Red is associated
with gasoline.
Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS
provide a fresh air opening in the heated
space of at least 2,800 cm
2
for each 29 kW of
heater output. Provide a larger opening if more
heaters are being used.
Minimum Ventilation Opening Needed
FF 45
FF 70
FF 125
FF 175
FF 215
1.4 ft.²
2.1 ft.²
3.8 ft.²
5.3 ft.²
6.5 ft.²
43 cm²
64 cm²
116 cm²
162 cm²
199 cm²
NEVER FILL THE FUEL TANK
INDOORS. ALWAYS FILL
THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE TANK.
CAUTION
NEVER REFUEL THIS HEATER
WHILE IT IS HOT OR
OPERATING. FIRE OR EXPLOSION COULD
RESULT.
DANGER
CARBON MONOXIDE POISONING
MAY LEAD TO DEATH!
DANGER
7
DO NOT USE GASOLINE OR
CRANKCASE DRAININGS.
WARNING
This appliance is designed to
operate safely at a minimum
ambient temperature of -20° C.
WARNING
Use caution when servicing in
wet areas. Disconnect power
from the power mains and keep all electrical
components from becoming wet. Only a
qualified technician should service the
heater
WARNING
A qualified technician is
required to install, adjust and,
where necessary, convert this heater for use
with other fuel types.
WARNING