NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2017, Lavorwash
Kerosene Forced Air Heater User’s Manual
Wiring Diagram
CONTROL PCB
POWER LAMP
(LED)
CN1
RED
RED
BLACK
BLUE
BLACK
BLACK
BLUE
RED
EARTH
GREEN
SPARK PLUG
IGNITOR
PUMP
MOTOR
CAPACITOR
3.5UF/450VAC
FAN 1
FAN 2
ACIN 1
WHITE
WHITE
EARTH
BLACK
WHITE
BLACK
GREEN
POWER
PLUG
AC 230V
50Hz
LIMIT
CONTROL
POWER
SWITCH
PHOTOCELL
BLACK
BLACK
CDS
CN2
YELLOW
FUSE
5A/250AVC
ACIN 2
Maintenance
PUMP PRESSURE:
While heater is operating, turn adjusting screw
clockwise to increase, counter-clockwise to
decrease pressure. Correct pump pressure is as
follows:
Model Number
Pump Pressure
FF 45
3.0 PSI / 0.21 BAR
FF 70
3.7 PSI / 0.26 BAR
FF 125
4.5 PSI / 0.31 BAR
FF 175
6.5 PSI / 0.45 BAR
FF 215
8.0 PSI / 0.55 BAR
Tolerance ± 10%
NOZZLES:
Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel could
make this necessary immediately. To clean dirt
from nozzle, blow compressed air through nozzle
front. It may be necessary to soak the nozzle in
paraffin to loosen any dirt particles.
Figure 18
Adjusting Screw
Pressure Valve
Figure 19
Nozzle
Nozzle Face
Burner Head
11
Figure 20: FF 45
Figure 21: FF 70 / FF 125 / FF 175 /
FF 215
CONTROL PCB
CN1
ORANGE
PINK
BLACK
BLACK
BLACK
WHITE
EARTH
GREEN
SPARK PLUG
IGNITOR
PUMP
MOTOR
CAPACITOR
3.5UF/450VAC
(70T-KFA-EU)
7uF/450VAC
(125T-KFA-EU)
(175T-KFA-EU)
(215T-KFA-EU)
MOTOR 1
MOTOR 2
ACIN 2
*
*
*
BLEU: FF 70
RED: FF 125 / FF 125 / FF 215
ACIN 1
FUSE
5A/250AVC
GREEN
EARTH
BLACK
WHITE
AC 230V
50Hz
POWER
PLUG
BLACK
POWER
SWITCH
LIMIT
CONTROL
PHOTOCELL
BLACK
BLACK
YELLOW
WHITE
WHITE
BLACK
BLACK
ROOM
SENSOR
R-TH
CN2
CN2
CDS
POWER LAMP
(LED)
THERMOSTAT
(TEMP. CONTROL
NOTE:
Models 125 / 175 / FF 215 have a
digital display.