NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
CONNECTED TO A POWER SOURCE
Diesel Fired Radiant Heater User’s Manual
© 2020, Lavorwash
Operation
Fueling The Heater:
Paraffin
For optimal performance of this heater, it is
strongly suggested that Kerosene be used.
Paraffin has been refined to virtually eliminate
contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the
heater. Using diesel fuel can cause excess soot
production. Do not use Bio-Diesel as this fuel will
damage your heater’s seals and filter.
- NEVER use fuel such as, benzene, alcohol, white
gas, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store Kerosene in the living space.
Kerosene should be stored in a well ventilated area
outside the living area.
- NEVER store Kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from
one season to the next. Paraffin deteriorates over
time. OLD KEROSENE WILL NOT BURN
PROPERLY IN THIS HEATER.
NOTE: Kerosene should only be stored
in a blue container that is clearly marked
“Kerosene.” Never store Kerosene in a red
container. Red is associated with gasoline.
Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS
provide a fresh air opening in the heated
space of at least 2,800 cm
2
(3 sq. ft) for each 29 kW / Hr. of heater output.
Provide a larger opening if more heaters are being
used.
As an example, a PT-125 SS will require:
- A two car garage door open 16 cm or
- A single car garage open 22 cm or
- Two (2) 82 cm windows open 38.5 cm
Minimum Ventilation Opening Needed
PT70-SS Plus
PT-125 SS
1950 cm
2
3484 cm
2
NEVER FILL THE FUEL TANK
INDOORS. ALWAYS FILL
THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE TANK.
CAUTION
NEVER REFUEL THIS HEATER
WHILE IT IS HOT OR
OPERATING. FIRE OR EXPLOSION COULD
RESULT.
DANGER
CARBON MONOXIDE POISONING
MAY LEAD TO DEATH!
DANGER
7
DO NOT USE GASOLINE OR
CRANKCASE DRAININGS.
WARNING
This appliance is designed to
operate safely at a minimum
ambient temperature of -20° C.
WARNING
Use caution when servicing in
wet areas. Disconnect power
from the power mains and keep all electrical
components from becoming wet. Only a
qualified technician should service the
heater
WARNING
A qualified technician is
required to install, adjust and
where necessary; convert this heater for use
with other fuel types.
WARNING