Maintenance - PT-125 SS

Long Term Storage:

1.  Unscrew the drain bolt and drain all fuel. 

(See Figure 17)

2.  Using a small amount of Kerosene or diesel, 

rinse and swirl the fuel inside the fuel tank.

NOTE: NEVER MIX WATER WITH FUEL. It will 

cause rust inside the tank. 

3.  Empty the tank completely.

IMPORTANT: Never store leftover Kerosene 

between seasons, using old fuel can  

damage heater.
Store Heater in a dry, well ventilated area.

 - Be sure that the storage area is free of dust 

and corrosive vapors. Repack the heater 

in the original packaging and keep user’s 

manual in an easily accessible place.

Service:

DO NOT TAMPER WITH THE UNIT. HAVE AN 

EXPERIENCED SERVICEMAN MAKE ANY 

NECESSARY ADJUSTMENT OR REPAIRS.
We suggest following a maintenance schedule as 

follows:

FUEL / FUEL TANK:

Flush tank every 200 hours of operation or as 

needed. DO NOT flush with water, use fresh 

Kerosene only.

SPARK PLUG:

Clean and re-gap every 600 hours of operation, 

or replace as needed After removing the Spark 

Plug, clean the terminals with a wire brush. 

(See Figure 18)

NOZZLES:

Nozzles should be cleaned or replaced at least 

once per heating season. Contaminated fuel 

could make this necessary immediately.

To clean dirt from nozzle, blow compressed air 

through nozzle front. It may be necessary to 

soak nozzle in clean diesel to help loosen any 

particles (Figure 19). 

11

Never service heater while it is 

plugged in or hot!

WARNING

TIP: Follow the long term storage 

instructions to flush the tank. 

SPARK PLUG

Figure 19

Figure 17

Figure 18

Summary of Contents for PT-125 SS

Page 1: ...RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION TO BE USED IN WELL VENTILATED COMMERCIAL INDUSTRIAL OCCUPANCIES This is an unvented portable heater that uses air Oxygen fr...

Page 2: ...NG INSTRUCTIONS Failure to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot produc...

Page 3: ...are foot 2 800 cm2 opening of outside air for every 29 kW Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use only the electrical power voltage and frequency specified...

Page 4: ...t Knob Can Tilt Up To 15 Wheel Drain Bolt Wheel Frame Fuel Cap Handle Specifications Model PT70 SS Plus PT 125 SS Rating kW Hr 20 5 36 6 Fuel Consumption L Hr 1 9 3 2 Fuel Tank Capacity L 15 1 53 Max...

Page 5: ...rews 2 Carry Handle Assembly 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws and tighten firmly Tools Needed Phillips Head Screw Driver Figure 3...

Page 6: ...m the shipping carton Tools Needed Phillips Head Screw Driver 8 mm open end wrench Assembly Instructions Tip Be sure to remove the axle from the side of the Styrofoam packaging Tip Use a power screwdr...

Page 7: ...ain structure on wheel frame and fasten with long screws provided 3 Attach safety guard to front of heater with screws provided 4 Attach Radiant Visors to the top and bottom rear of the Radiant Cone A...

Page 8: ...ociated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater only in well ventilated areas Refer to Safety Information on pages 1 2 for information about Car...

Page 9: ...n the PC board If the heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1...

Page 10: ...inal packaging and keep user s manual in an easily accessible place Service DO NOT TAMPER WITH THE UNIT HAVE AN EXPERIENCED SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS We suggest following a m...

Page 11: ...y to soak nozzle in clean paraffin or diesel to help loosen any particles See Figure 13 PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a...

Page 12: ...ble place Service DO NOT TAMPER WITH THE UNIT HAVE AN EXPERIENCED SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS We suggest following a maintenance schedule as follows FUEL FUEL TANK Flush tank e...

Page 13: ...Maintenance PT 125 SS Service Continued PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a cotton swab and water or alcohol to clean the l...

Page 14: ...ith clean fresh paraf fin diesel 6 Inspect all electrical connections See Wiring Diagrams Page 14 7 Re attach Transformer wires to Spark Plug 8 Replace Transformer Fan does not operate when heat er is...

Page 15: ...R UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Diesel Fired Radiant Heater User s Manual 2020 Lavorwash 14 Wiring Diagrams AC230V 50Hz 250V 3 15A PT70 SS Plus PT 125 SS Figure 23 Figu...

Page 16: ...23 0285 01 02 75 00702059 3 Fuel Pipe Assembly 75 023 0345 75 024 0725 4 Fuel Hose 75 024 0700 75 024 0700 5 Fuel Gauge 75 022 0210 01 04 75 007010071 6 Fuel cap 70 006 0135 70 006 0140 7 Cooling Fan...

Page 17: ...00 01 04 75 007010078 29 Burner Blade 75 036 0120 01 01 75 007010700 30 Nozzle 75 036 0435 01 01 75 007020215 31 Nipple 75 040 0610 01 01 75 007010203 32 Diffusion cap 75 036 0500 42 300 0010 33 Blowe...

Page 18: ...TED TO A POWER SOURCE Diesel Fired Radiant Heater User s Manual 2020 Lavorwash Exploded View PT 125 SS 17 ALWAYS contact the manufacturer of this heater before replacing any parts other than those spe...

Page 19: ...72 312520120 22 Back Cover 72 013 0110 01 02 72 012510061 23 Panel sub PCB 72 014 0105 01 04 72 012510107 24 Blower Motor 72 045 0100 01 04 72 312520116 24 internal parts Blower Housing Blower Wheel A...

Page 20: ...______________________ Serial ________________________________ Date of Purchase ________________________ Locating Your Serial Number Your serial number can be found on a blue label on the left side co...

Reviews: