Filling the pump housing (fig. A)
After each use the pump housing must be drained.
n
Remove the water hoses present.
n
Remove the screw from the bleeding point (7).
n
Tilt the machine forward and empty the pump
housing.
n
Reinsert the screw and tighten it securely.
@
Never fully close the bleeding point
if you leave the machine in an area
colder than 0 °C.
TECHNICAL DATA
EG-P 3600
Mains voltage
V 230
Mains frequency
Hz 50
Power input
W 1,000
Max. pump capacity
l/h 3,600
Max. pumping depth
m 8
Max. pumping height
m 45
Max. water temperature
°C 35
Weight
kg 6.3
Level of sound pressure measured according to
ISO 3744:
EG-P 3600
L
pA
(sound pressure)
dB(A) < 70
GUARANTEE
This product has been thoroughly checked in
the factory. After purchase date a full 2 year’s
guarantee applies to material and production
defects. A guarantee of 6 months applies to
rechargeable batteries/battery packs and chargers.
Guarantee conditions
If the product shows defects as a result of
material and production defects during the
period of guarantee, we guarantee free repair
on condition that:
the product has been used properly and for
the purpose for which it has been intended.
repairs are professionally carried out by
a person appointed by the supplier.
the proof of purchase will be submitted.
Accessories and parts showing normal wear are
not covered by any guarantee.
If, during the period of guarantee, a defect
emerges that cannot be repaired, free
replacement of the product takes place.
[
ENVIRONMENT
Should your product need replacement after
extended use, do not put it in the domestic waste
but dispose of it in an environmentally safe way.
DECLARATION Of CONfORMITY
%
Lavorwash S.p.A. declares that the machines:
Water pump
EG-P 3600
have been designed in compliance with the
following standards:
EN 50366, EN 550141, EN 550142,
EN 603351, EN 60335241, EN 6100032,
EN 6100033
and in accordance with the following directives:
2004/108/EC, 2006/95/EC
Pegognaga, 022010
Giancarlo Lanfredi
Director
Lavorwash S.p.A., via J. F. Kennedy, 12 Italy 46020 Pegognaga (MN)
IMPORTANT (fOR UK ONLY)
If the moulded 3 pin plug attached to this unit is
damaged and needs replacing, it is important
that it is correctly destroyed and replaced by an
approved BS 1363/5A fused plug and that the
following wiring instructions are followed.
The wires in this mains lead are coloured in
accordance with the following code:
blue
neutral
brown
live
green and yellow earth