TROUBLES
CAUSES
SOLUTIONS
1 1 THE GENERATOR
PRESSURE DOES NOT
INCREASE
1- Pressure switch
1-Burner
1-Resistance temperature
detector PT100
1-Check the pressure
switch
1-Check electrodes, diesel
nozzle
1-Check that the tempera-
ture is at least 150°C
- Authorized After Sales
Service
- The user
- The user
2 2 THE PUMP CANNOT
RUN
2.1 It loads no water
2.2 Sound allarm
2.1 The water tank is empty
2.1 Pump
2.1 Clogged filter
2.2 Lack of water in the tank
2.2 Check the electronic level
2.2 water solenoid valve
2.1 Fill the tank
2.1 Replace the pump
2.1 Clean the filter
2.2 Fill the tank
2.2 Replace the solenoid
valve
2.2 Check and eventually
replace it
- The user
- Authorized After Sales
Service
- The user
- The user
- Authorized After Sales
Service
3 THE SAFETY VALVE
OPENS REPEATEDLY
3.1 It keeps on
loading water
3.1Boiler water level probe
3.1Pressure switch
3.1Safety valve
3.1Clean the probe dischar-
ging boiler pressure
3.1Replace the pressure
switch and check that the
connection discharging
tube is free from incru-
stations.
3.1Replace the safety valve
- Authorized After Sales
Service
- Authorized After Sales
Service
- Authorized After Sales
Service
The safety valve can be
replaced only by or qua-
lified service center.
Safety valve replacement
must be set at 12 bar
and be accompanied
by certified PED as provi-
ded for category IV
EN
23
Summary of Contents for MAJOR
Page 5: ...5 mod 220 240 V mod 2 Way mod 12V...
Page 52: ...01 02 03 04 05a 05b 5 05c 05d 05e 06 30 RU 52...
Page 53: ...19 20 21 22 23 24 XX XY XJ K1 0 K2 07 08 11 OFF 12 13 14 16 17 18 RU 53...
Page 54: ...K3 K4 K5 K6 K7 K8 K9 K10 V11 V12 K13 V14 V15 K16 K17 K18 K19 K20 RU 54...
Page 58: ...0 OFF 1 2 I ON II ON 3 I 1 0 OFF 2 0 OFF 3 0 1 BAR F Optional OFF V15 180 C RU 58...
Page 61: ...8 9 2002 96 EC 27 01 03 RU 61...
Page 62: ...62...
Page 63: ...63...