Rev A 71918 Page | 4
Product Setup & Use
•
DISCONNECT THE HOSE FROM THE HANDYFOAM AFTER EACH USE.
•
SHUT OFF THE WATER VALVE AFTER EACH USE.
Troubleshooting
Operating Mode
Wash Mode
1. Connect the hose to the trigger sprayer.
Refill the tank with chemical.
2. Insert the desired metering tip.
3. Insert the suction line.
4. Connect the top cover to the gun using the quick coupler.
5. Apply the foam, activating the valve.
Shut off the trigger.
Disconnect the tank from the gun using the quick coupler.
Rinse Mode
1. Activate the trigger sprayer to rinse with clean water, once it
has been disconnected from the tank.
Disconnect the gun from the system, make sure to clean the
system.
How to use the Quick Coupler
1.
Pull back the coupler ring.
2.
Introduce the nipple.
3.
Release the coupler ring.
Problem
Cause
Solution
No
chemical
suction.
1. Suction filter clogged.
1. Clean or replace.
2. Tip clogged.
2. Clean or replace.
3. Water pressure not sufficient.
3. Minimum = 26 PSI
4. Top cover eductor clogged with
calcium.
4. Clean (using descale chemical) or replace the top
cover.
Foam not
sufficient.
1. Water pressure not sufficient.
1. Minimum = 26 PSI
2. Suction filter or tip clogged.
2. Clean or replace.