5.4. Electric connection
connect the machine power cord according to the in-
structions shown in “electric diagrams” section.
Attention
It is recommended to install a protection switch on
the electric network.
Attention
Carry out all electric connections with the power
supply disconnected.
5.5. Machine start up
Attention
Before starting the machine, make sure that the level
of water in the boiler is higher than the
minimum level on the level-check win-
dow (A).
If there is no water (first installation or after boiler main-
tenance), it is necessary to fill the boiler in advance in
such a way to prevent the overheating of the heating ele-
ment.
Proceed as follows :
- open the water tap of the water mains and of the sof-
tener;
- turn the switch to position one “1” (electric power sup-
ply to the pump for automatic boiler filling
and machine services) and wait for the
boiler to be automatically filled with water;
- turn the switch to the position “2” (full electrical power
supplied, including the heating element in the boiler)
and wait for the machine to warm up completely.
Attention
During the machine’s warm-up phase (about 20 mi-
nutes), the safety valve will release steam for a few
seconds until the valve itself closes.
Before using the machine, carry out some dry cy-
cles with the capsule holders attached for a few se-
conds, to release any air which may be in the circuit,
so that the brewing units are completely heated.
Before using the machine dispense few coffees to
check the operating pressure of the machine.
6.
CONFIGURATION
6.1. Programming
Attention
Machine programming must be carried out by te-
chnical staff. Be careful when accessing the inside
of the machine the temperature of some compo-
nents is very high and there are powered parts.
6.1.1. Programming of coffee doses
Put the programming lever (1), situated under the ma-
chine boiler cover, to the on position.
Place the cup under the dispensing spout.
Press the PRoG/SToP key (6) for at least 5 seconds: all
the leds of the dose keys light up.
Press the desired dose key: for instance the (4) key.
When the desired dose is reached, confirm it by pres-
sing the PRoG/SToP (6) key.
Maintenance manual for technical assistance
11
Manual code 10066846 / Rel. 0.00 / March 2012
A
1
2
0
ON
1
6
4