The machine correctly delivers
coffee, steam or hot water but
there is water leakage inside
the structure.
If the leak occurs on the 2-way
solenoid valve nipple.
•
The connection is
damaged or not tight
enough.
If the leak occurs on the rapid
insertion connections of the
teflon pipe.
If the leak occurs on the 3-way
solenoid valve.
• The nuts are not tight
enough on the solenoid
valve.
If the leak occurs on the pump.
• The nut is insufficiently
tightened on the pump
connection.
•
The 0-ring seal present in
the connection is damaged.
•
The pump entry pipe is
not correctly fitted and it is
blocked by a safety strip.
1
Replace the connection or
check tightening
1
Replace the connections.
1
Check the tightening and
adjust it if necessary.
1
Check the tightening and
adjust if necessary.
2
Replace the O-ring seal.
3
Check and ensure the
correct insertion of the pipe
in its seat.
The coffee is regularly
delivered but the kickback
element fails to indicate the
approach of the deliveries.
1
Replace the component.
• Defective kickback element.
“E