Electrical Requirements
Part No. 70476501ENR7
51
Electrical Requirements
Electrical Requirements
WARNING
To reduce the risk of electric shock, fire, explosion,
serious injury or death:
•
Disconnect electric power to the tumble dryer
before servicing.
•
Close gas shut-off valve to gas tumble dryer
before servicing.
•
Close steam valve to steam tumble dryer before
servicing.
•
Never start the tumble dryer with any guards/
panels removed.
•
Whenever ground wires are removed during
servicing, these ground wires must be
reconnected to ensure that the tumble dryer is
properly grounded.
W002R1
WARNING
To reduce the risk of fire and electric shock, check
with a qualified service person for proper grounding
procedures. Improper connection of the equipment
grounding conductor may result in a risk of electric
shock.
W068R1
WARNING
To reduce the risk of fire and electric shock, if
electrical supply is coming from a three phase
service, DO NOT connect a “High Leg” or “Stinger
Leg” to a single phase machine. On a three phase
machine, if there is a “High Leg” or “Stinger Leg” it
should be connected to L3.
W069
IMPORTANT: Electrical connections must be made
by a qualified electrician using data on serial plate,
installation manuals and wiring diagram provided with
machine and according to local codes. Install a circuit
breaker as close to the tumble dryer as possible. If
more than one tumble dryer is being installed, a circuit
breaker must be provided for each.
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses to
avoid the possibility of “single phasing” and causing
premature failure of the motors.
WARNING
In case of servicing (or putting the tumble dryer
out of order), disconnect the tumble dryer from the
main supply by switching off the circuit breaker.
W796
Wiring Diagram
The wiring diagram is located in the junction or contactor box.
The wiring diagram part number is in the lower portion of the
electrical data on the serial plate.
Grounding Instructions
NOTE: To ensure protection against shock, this
tumble dryer MUST be electrically grounded in
accordance with the local codes, or in the absence
of local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, or local codes. Electrical work should be done
by a qualified electrician.
This tumble dryer must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
tumble dryer must be connected to a grounded metal, permanent
wiring system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the appropriate
ground location.
•
Metal conduit and/or BX cable is not considered ground.
•
Connecting the Neutral from the electrical service box to the
tumble dryer ground screw does not constitute a ground.
•
A dedicated ground conduit (wire) must be connected
between the electrical service box ground bar and tumble
dryer ground screw.