13
OPERATION INSTRUCTIONS
Before Turning Gas Supply ON
Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a building,
or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline and other flammable vapors
or liquids.
Ensure that there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris.
Be sure any component removed during assembly or servicing is replaced and fastened prior to
starting.
Before Lighting
Thoroughly inspect your heater before each use.
If relighting a hot heater always wait at least 15 seconds.
WARNING: DO NOT attempt to operate heater until you have read and understood all
precautions. Failure to do so can result in serious personal injury, death or property damage.
Lighting Instructions
1) Turn the control knob to "OFF" ( 1 ) position.
2) Turn LP cylinder gas valve to fully open position.
3) Push in gas control knob and turn counter-clockwise to "IGNITE PILOT" ( 2 )position, this will
light the pilot. If needed, keep depressing and turning control knob counter-clockwise until the pilot
lights.(You will hear 1 clicking noise).
4) Once the pilot is lit, continue to keep the control knob depressed for at least 30 seconds, After 30
seconds release control knob.
5) If pilot does not stay lit, repeat steps 3 and 4.
6) If pilot still does not stay lit, then:
a) Push in gas control knob and turn counter-clockwise to "IGNITE PILOT" ( 2 ).
b) keep depressing the control knob, put long stem lighter into the ignition hole on the emitter
screen to light the pilot.
c) repeat step 4.
7) Push in and turn control knob counter clockwise to "HIGH" ( 4 ) position, If you want a lower
temperature, push in the control knob and turn clockwise to the "LOW" ( 3 ) position.
PUSH TO TURN
1 OFF
2 IGNITE PILOT
3 LOW
4 HIGH