background image

DATA BADGE FOR THE Y7 MOBILE PATIO HEATER 

 

APPLIANCE CODE: 

Y7

 

TOTAL HEAT INPUT:   

61000BTU   

GAS CATEGORIES: 

I

3B/P(50)

 

TYPES OF GAS: 

LPG mixtures 

GAS PRESSURE: 

50 mbar LPG mixtures 

INJECTOR SIZE: 

1.30 mm 

FOR USE OUTDOORS AND IN WELL VENTILATED AREAS 
THIS APPLIANCE IS NOT FOR DOMESTIC USE 
WARNING: ACCESSIBLE PARTS MAY BE VERY HOT. KEEP YOUNG CHILDREN 
AWAY 
READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE. THE 
APPLIANCE  MUST  BE  INSTALLED  IN  ACCORDANCE  WITH  THE 
INSTRUCTIONS AND LOCAL REGULATIONS 
CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE. 
THE  USE  OF  THIS  APPLIANCE  IN  ENCLOSED  AREAS  CAN  BE  DANGEROUS 
AND IS PROHIBITED 
WELL VENTILATED AREAS MUST HAVE A MINIMUM OF 25% OF THE SURFACE 
AREA OPEN.    THE SURFACE AREA IS THE SUM OF THE WALL SURFACE. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                      9 
 
 
 

Summary of Contents for PANDORA Y7

Page 1: ......

Page 2: ...2 Parts list Y7 3 Assembly Procedures 4 Position logs and glass ball on the burner 5 Heater Stand and Location 6 Gas Requirements 6 Leakage Test 6 Lighting instructions 7 Storage 7 Cleaning and Care 7 Data badge1 8 Data badge2 9 Problems Check List 10 ...

Page 3: ...k for leaks Do not use the heater until all connections have been leak tested Turn off the gas valve immediately if smell of gas is detected Do not transport heater while it is operating Do not move the heater after it has been turned off until the temperature has cooled down Control compartment burner and circulation air passageways of the heater must be kept clean Frequent cleaning may be requir...

Page 4: ...Exploding Drawing Y7 2 ...

Page 5: ...tom door damper 1 28 Pilot protector 1 9 Turn knob bracket 1 29 Top mesh 1 10 Turn knob 1 30 Top panel of combustion chamber 1 11 Outer middle decorated bar 1 31 Side tempered glass 2 12 Gas valve 1 32 Glass slot 1 13 Inner middle decorated bar 1 33 Front tempered glass 1 14 Inner piece 2 34 Pilot 1 15 Inner panel of Top back door 1 35 Pilot bracket 1 16 Outer panel of Top back door 1 36 Front sup...

Page 6: ... STEP 2 Screw the knob on tank door with screw we supplied in one set Use 2 pcs of M8 screw to contact handrail with heater body STEP 3 STEP 4 if go with back wheel Screw four wheels on heater body two wheel without brake for front side and two for behind Position top space mesh on the top board then screw it on 4 ...

Page 7: ...osition ceramic logs on the burner Pandora Y7 1 Take out ceramic logs decorated oblate glass ball from carton 2 Refer to following picture for position the ceramic logs and decorated oblate glass ball 5 ...

Page 8: ...ses A dented rusted or damaged propane tank may be hazardous and should be checked by your tank supplier Never use a propane tank with a damaged valve connection The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder Never connect an unregulated propane tank to the heater LEAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipm...

Page 9: ...linder valve or regulator switch to the OFF position and then turn the control knob on the appliance clockwise to the OFF position WARNING If the burner fails to ignite turn the control knob off clockwise and also turn the cylinder valve off Wait five minutes before attempting to relight with ignition sequence CLEANING AND CARE Make sure all the cleaning is done after turn off the heater and cooli...

Page 10: ...CE IS NOT FOR DOMESTIC USE WARNING ACCESSIBLE PARTS MAY BE VERY HOT KEEP YOUNG CHILDREN AWAY READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS AND LOCAL REGULATIONS CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE THE USE OF THIS APPLIANCE IN ENCLOSED AREAS CAN BE DANGEROUS AND IS PROHIBITED WELL VENTILATED ...

Page 11: ...WARNING ACCESSIBLE PARTS MAY BE VERY HOT KEEP YOUNG CHILDREN AWAY READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS AND LOCAL REGULATIONS CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE THE USE OF THIS APPLIANCE IN ENCLOSED AREAS CAN BE DANGEROUS AND IS PROHIBITED WELL VENTILATED AREAS MUST HAVE A MINIMUM O...

Page 12: ...10 ...

Page 13: ......

Page 14: ......

Page 15: ......

Reviews: