LMW – Trade Line Owner’s Manual 

      

 

Rough in the wiring on a single 120VAC, 20 amp, GFCI protected dedicated circuit for each accessory installed 
on the tub. 

WARNINGS:   
1)  All electrical connections must be made by a licensed certified electrician in accordance with the 
requirements of the National Electrical Code and applicable state and local codes and procedures. 
2)  All circuits connected to this unit must be equipped with Ground Fault Circuit Interrupter (GFCI) 
protection.  It is the tub installer’s responsibility to wire the circuit with GFCI. 
3)  All bathtubs equipped with a heater require two dedicated circuits.  One for the whirlpool system and 
one for optional heater. 
4)  DO NOT splice a longer cord to the power supply cord and DO NOT connect to an extension cord. 

 

All whirlpool, air systems, and heaters are equipped with a molded plug on the end of a power supply core.  
Install a separate, dedicated 120VAC, 20 Amp GFCI protected electrical wall plug outlet inside the access panel 
for each accessory equipped on the tub.  For example, if the tub is equipped with a whirlpool system only, 
then one GFCI wall plug outlet is necessary.  If the tub is equipped with both whirlpool system and a heater 
then two separate circuits with GFCI wall plug outlets are required.  Be sure to count the number of 
accessories before installing the GFCI wall outlets.  Also, the power supply cords equipped with each accessory 
are only 2.5’ long so locate the GFCI wall outlet within 1.5’ of the intended accessory.  

 

Electrical Requirements 

1.5 hp Pump – 120V, 7.5 Amps 

Whirlpool heater – 120V, 12.0 Amps 

2.5 hp Pump – 120V, 13.5 Amps 

Air / Soaker heater – 120V, 12.5 Amps 

1 hp Blower/Heater – 120V, 12.0 Amps 

Air / Soaker heater – 240V, 16.0 Amps 

Ozonator – 120V, 1.0 Amps 

 

 

Please note

, that when sizing the electrical circuits to power the unit, you should always check the rating 

labels on equipment because there could be changes. 

 

Install fill valves and spout in the desired locations.  Note, due to various possible fill valve and spout locations, 
the holes are not drilled at the factory.  Make certain that the spout is long enough to clear the interior rim of 
the tub.  If installing fill valves on the deck of the tub, be sure that you have enough clearance for connections 
of valve to tub and water connections before drilling/cutting into tub.  Seal the joints under the tub rim and 
against the wall with a water resistant seal.  Then install a standard 1.5” trap to the drain and overflow. 
Before proceeding, make a final operational check by filling the tub with water to the overflow and operate for 
at least 5 minutes.  Leave the water in the bath for 30 minutes, check the connections for leaks during and 
after operation.  Complete the installation with desired trim material on the back wall, side walls, and down 
exposed interior walls. 

 

Summary of Contents for Trade series

Page 1: ...OOLS TRADE LINE OWNER S MANUAL For your installation operation and maintenance needs Whirlpools Air Baths Combo Baths Soakers WATER TEST PRIOR TO INSTALLATION Laurel Mountain Whirlpools Service Center...

Page 2: ...urel Mountain Whirlpools tub or it s hardware will void the warranty of this product if written approval is not obtained from the manufacturer Your Laurel Mountain Whirlpools tub was created to your o...

Page 3: ...d install a 1x stop to stud wall for lip to rest on to prevent deflection At this time check to see if any wiring needs to be completed see wiring instructions Since a great variety of installations a...

Page 4: ...ccessories before installing the GFCI wall outlets Also the power supply cords equipped with each accessory are only 2 5 long so locate the GFCI wall outlet within 1 5 of the intended accessory Electr...

Page 5: ...sh and will retain its high luster for years with proper care Never use an abrasive cleaner or pad to clean your bath tub Always use a soft cloth or sponge along with a spray liquid non abrasive bath...

Page 6: ...of a supply cord Check your local codes and install a 120VAC 20amp GFCI protected dedicated circuit wall outlet within 1 5 from the heater unit Plug the cord into the outlet Every time the whirlpool...

Page 7: ...d period of time it is possible that the thermic protection has shut off the motor Allow to cool off for at least 30 minutes before further use PUMP Won t Start Motor hums Check to see if on off switc...

Reviews: