background image

LAUNCH                                                       X-431 Russia GAZ Diagnosis

 

Trademark Information 

 

LAUNCH

 is a registered trademark of 

LAUNCH TECH  CO., LTD. (also called 
LAUNCH for short) in China and other countries. 
All other LAUNCH trademarks, service marks, 
domain names, logos, and company names 
referred to in this manual are either trademarks, 
registered trademarks, service marks, domain 
names, logos, company names of or are 
otherwise the property of LAUNCH or its 
affiliates. In countries where any of the 
LAUNCH trademarks, service marks, domain 
names, logos and company names are not 
registered, LAUNCH claims other rights 
associated with unregistered trademarks, 
service marks, domain names, logos, and 
company names. Other products or company 
names referred to in this manual may be 
trademarks of their respective owners. You may  
not use any trademark, service mark, domain 
name, logo, or company name of LAUNCH or 
any third party without permission from the 
owner of the applicable trademark, service 
mark, domain name, logo, or company name. 
You may contact LAUNCH by visiting Launch at 
www.cnlaunch.com, or writing to  LAUNCH, 
Xinyang Building, Bagua 4th Road, Shenzhen, 
Guangdong Province, P. R. C., to request 
written permission to use Materials on this 
manual for purposes or for all other questions 
relating to this manual. 

Copyright Information 

 

Copyright ©   2000 by LAUNCH TECH. CO., LTD. 
All rights reserved. No part of this publication 
may be reproduced, stored in a retrieval system, 
or transmitted in any form or by any means, 
electronic, mechanical, photocopying, recording 
or otherwise, without the prior written 
permission of LAUNCH. The information 
contained herein is designed only for the use of 
this unit. LAUNCH is not responsible for any 
use of this information as applied to other units.   
Neither LAUNCH nor its affiliates shall be liable 
to the purchaser of this unit or third parties for 

damages, losses, costs, or expenses incurred 
by purchaser or third parties as a result of: 
accident, misuse, or abuse of this unit, or 
unauthorized modifications, repairs, or 
alterations to this unit, or failure to strictly 
comply with LAUNCH operating and 
maintenance instructions.   
 
LAUNCH shall not be liable for any damages or 
problems arising from the use of any options or 
any consumable products other than those 
designated as Original LAUNCH Products or 
LAUNCH Approved Products by LAUNCH.   
 

General Notice 

 

??

Other product names used herein are for 
identification purposes only and may be 
trademarks of their respective owners. 
LAUNCH disclaims any and all rights in 
those marks.   

??

There is a possibility that this unit is 
inapplicable to some of the vehicle models 
or systems listed in the diagnosis section 
due to different countries, areas, and/or 
years. Do not hesitate to contact LAUNCH 
if you come across such questions. We are 
to help you solve the problem as soon as 
possible. 

 

Disclaimer 

 

??

To take full advantage of the unit, you 
should be familiar with the engine. 

??

All information, illustrations, and 
specifications contained in this manual are 
based on the latest information available at 
the time of publication. The right is 
reserved to make change at any time 
without notice.   

 

Summary of Contents for X-431 PADII

Page 1: ...r by any means electronic mechanical photocopying recording or otherwise without the prior written permission of LAUNCH The information contained herein is designed only for the use of this unit LAUNCH is not responsible for any use of this information as applied to other units Neither LAUNCH nor its affiliates shall be liable to the purchaser of this unit or third parties for damages losses costs...

Page 2: ...Connector 1 Diagnostic Socket Location 1 Pin Definitions 1 Connection 1 Operation 2 Entering Function Menu 2 Read Current DTC 4 Read Stored DTC 4 Read Repeated DTC 4 Erase DTC 5 Data Stream 5 Work Flag 6 ADC Channel 7 Passport 7 Program 7 Vehicle 8 Adjust 8 Control Block 8 Actuator Test 8 ...

Page 3: ...or connection before performing diagnosis To vehicle diagnostic socket Figure 02 Insert the C F card into the CF card slot Note keep the face labeled UPSIDE upward and make sure the card is fully seated Insert one end of the main cable into the diagnostic socket on SMARTBOX Connect the other end of the main cable to the GAZ 12PIN diagnostic connector Connect the other end of the diagnostic connect...

Page 4: ...X INFO to display hardware and software version of SMARTBOX HELP to display help information START to start diagnosis Click START button the screen will display the vehicle make menu as shown in Figure 04 Figure 04 Button descriptions BACK to return to the previous interface PAGE UP to display the previous page it is inactive if the current page is the first page PAGE DOWN to display the next page...

Page 5: ...reen will display the message as shown in Figure 07 Figure 07 Button descriptions OK to go on the test Click OK button X 431 will read the version information of ECU on the tested vehicle as shown in Figure 08 Figure 08 After reading the version information of ECU the screen will display the system menu as shown in Figure 09 Figure 09 The test procedures of the two systems are similar here we only...

Page 6: ...ent DTC of the tested vehicle if any If the vehicle has no current DTC the screen will display a message as shown in Figure 12 Figure 12 Click OK to return to the function menu Read Stored DTC Click READ STORED DTC in the function menu The screen will display the stored DTC of the tested vehicle if any If the vehicle has no stored DTC the screen will display a message as shown in Figure 13 Figure ...

Page 7: ...n Figure 14 Figure 14 Click YES to perform erasing click NO to cancel erasing and return After erasing the screen will display a message as shown in Figure15 Figure 15 Click OK to returnto the function menu Data Stream Click DATA STREAM in the function menu X 431 will display the data stream items as shown in Figure16 Figure 16 Click PAGE DOWN button to display the data stream items on the next pa...

Page 8: ...ck DIGITAL on the GRAPHIC 2 display mode to display the live data stream value again The three display modes DIGITAL GRAPHIC 1 and GRAPHIC 2 can be switched in turn Work Flag Click WORK FLAG in the function menu X 431 will display the data stream items as shown in Figure19 Figure19 Click PAGE DOWN button to display the data stream items on the next page To view the work flag status click the corre...

Page 9: ... data stream items as shown in Figure 22 Figure 22 To view the live data stream click the corresponding items to select as shown in Figure 23 Figure 23 After selecting click OK to display the live data stream Passport Click PASSPORT in the function menu X 431 will display the sub function menu as shown in Figure 24 Figure 24 Program Click Program in the passport function menu The screen will displ...

Page 10: ...Adjust in the passport function menu The screen will display the data stream value related to adjust as shown in Figure 27 Figure 27 Control Block Click Control block in the passport function menu The screen will display the data stream value related to control block as shown in Figure 28 Figure 29 Actuator Test Click ACTUATOR TEST in the function menu X 431 will display actuator menu as shown in ...

Page 11: ...e corresponding items For example click Injector 1 the screen will display an interfaceas shown in Figure 31 Figure 31 Click ON or OFF the injector 1 will be switched ON or OFF After test the screen will display a message as shown in Figure 32 Figure 32 Click OK to return to the actuator menu User can test another actuator by clicking it as required ...

Page 12: ...representation or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Order Information Replaceable and optional parts can be ordered directly from your LAUNCH authorized tool supplier Your order should include the follow...

Reviews: