5 Working with the ADAS Calibration Tool
The calibration operation should be performed strictly following the on-screen
instructions on the diagnostic tool. For some vehicle models, calibration pattern and
calibration tool are not mandatory. But for some camera-based ADAS, the calibration
can not be done without the help of calibration tool and calibration pattern. In this case,
for the positioning of the calibration tool and vehicle, it is necessary for the user to
manually finish it.
The following steps are necessary to work with the ADAS Calibration System:
1. Place the ADAS calibration panel in front of (for front camera) the vehicle (Refer to
Chapter 5.2.1.1).
2. Place the ADAS calibration panel centred in front of the vehicle (Refer to Chapter
5.2.1.2).
3. Place the ADAS calibration panel in parallel with the vehicle (Refer to Chapter
5.2.1.3).
4. Adjust the height of the calibration panel (See Chapter 5.2.1.4).
5.1 Precondition for the Use of the ADAS Calibration Tool
Regard the following in order to use the ADAS calibration tool:
• Vehicle system is working properly.
• No trouble codes stored in ECU memories.
• Prepare vehicle-specific calibration reference pattern.
• A LAUNCH’s scanner supporting ADAS system calibrating is required (sold
separately).
• Front & rear axle track is properly adjusted.
• To make you work smoothly and calibrate accurately, please make sure the following
workstation requirement are met (See Chapter 5.1.1 ~ Chapter 5.1.3).
5.1.1 Workstation size
5.1.1.1 For front cameras
Distance A = about 2.8m (the width of the cross member)
Distance B = about 1m (from the cross member to the wall)
Distance C = at least 0.5m (from the edge of the cross member to other obstacles)
Distance D = varies from vehicle to vehicle, about 1.5m is strongly recommended (from