Filter Parameter 

After  the  replacement  of  filter,  enter  the  interface  of  filter  parameter.  Enter  the 
password and reset the service time of the filter. 

 

Summary of Contents for VALUE-500

Page 1: ...s instead of Launch original products or Launch recognized products Declaration Other product names mentioned in the user manual are aimed to describe the device usage The registered trademarks still...

Page 2: ...VALUE 500 Mobile Refrigerant Recovery Recycling and Charging Unit Touchscreen Version...

Page 3: ...own below 6 H i g h a n d L o w P r e s s u r e V a l v e s O p e r a t i n g G u i d e l i n e s 7 Preparation Before Use 9 Operation Procedures 9 I Refrigerant Cylinder Refill 9 II Recycle 10 III Va...

Page 4: ...essure of external factors 7 To ensure the refill function refrigerant cylinder must contain no less than 3kg refrigerant otherwise the refill may fail 8 Bubbles are always produced while discharging...

Page 5: ...refrigerant cylinder of the equipment and during the recovery the refrigerant is purified and regenerated Vacuum It can evacuate any remaining gas or water from the equipment and the system Recharge...

Page 6: ...3...

Page 7: ...4 Appearance Introduction 1 Outside View 2 Rear View Handle AC 220V Fuse Vial filling valve Remove the retaining screw before using Power switch...

Page 8: ...5 3 Side View 4 Operation Panel Refrigerant oil inlet Used oil bottle Low Pressure Valve High Pressure Valve Window Touchscreen...

Page 9: ...5 Internal Structure Picture1 Picture2 Heat exchanger Condenser Cooling fan Filling valve for internal refrigerant cylinder Dry filter Vacuum pump Compressor Oil discharge solenoid valve Oil separato...

Page 10: ...ction to Car as shown below Filling pipe ball valve Electronic scale protection screw Filling pipe red Recycling pipe blue Recycling pipe ball valve Electronic scale for internal liquid reservoir Inte...

Page 11: ...Turn off the high and low pressure valves As shown below turn off the high low pressure valve is to tighten the valves counterclockwise based on the reverse direction of the arrow the arrow marked op...

Page 12: ...kwise based on the direction of the arrow the arrow marked open on the valve on the high and low pressure valves Rotate the air conditioning quick couplings clockwise Sketch map of turning on the air...

Page 13: ...ng the factory Refrigerant must be refilled before operation The recommended refill weight is 3 6kg Operation is as follows 1 Attach the blue hose to the main equipment s low pressure valve 2 Attach t...

Page 14: ...and click Confirm to continue After the procedure completed normally the system shows the following interface click Exit to return to main interface 2 Recycle Recycle is recycling the purged refriger...

Page 15: ...us to set time then select run Any refrigerant in the pipeline would be recycled automatically then the vacuum procedure would start Dwell time comes after vacuum procedure As the time ends it enters...

Page 16: ...s OK to start and release to stop Exit the system upon completion 4 Charge On the homepage double click charging to enter the filling procedure You can select the large or the small bottle filling Aft...

Page 17: ...quipment pipelines Press exit upon completion 5 Purge Purge function is to clean the car piping system Enter the cleaning procedure press plus or minus to add or reduce the forward and reverse cleanin...

Page 18: ...15...

Page 19: ...16 After cleaning is complete it will automatically enter the recycling procedure Press exit upon completion 6 Quick Maintenance On the homepage click Fast Service to enter the procedure...

Page 20: ...e forward and reverse cleaning time and to set the number of cycles Before cleaning ensure that there is more than 2KG refrigerant in the tank then press OK to start After the cleaning is complete it...

Page 21: ...cuum is complete the equipment will sound a beep and start to maintain pressure If there is no leakage in the pipeline you could skip this procedure and fill the refrigerant oil into refrigerant cylin...

Page 22: ...e or the small bottle filling After selecting the fill mode ensure that there is sufficient refrigerant Then long press OK to start and release to stop After completion press EXIT it will automaticall...

Page 23: ...20 Press exit upon completion 7 Equipment Maintenance Click Equipment Maintenance in the main interface to enter the maintenance procedure...

Page 24: ...ale First input the weight of reference weight parameter 2000g for example Then click OK and go on to the next step Place 2kg weight should be equal to the weight input in previous step on the tray Wa...

Page 25: ...22 Electronic Scale Reset Ensure there is no refrigerant inside the cylinder Wait until weight parameter become unchanged and click OK to finish intelligent reset Equipment Information...

Page 26: ...23 Filter Parameter After the replacement of filter enter the interface of filter parameter Enter the password and reset the service time of the filter...

Page 27: ...ation presentation or promise related to Launch products Statement of Disclaimer The above warranty clause can substitute for any other form of warranty clauses Purchase Order Replaceable parts and op...

Page 28: ...may differ from those shown in the manual Please refer to the actual product We have tried our best to make all the descriptions in the book accurate but there are still some inconveniences If you ha...