PROGRAMMING OF BATCHING CONSTANTS
From weight display press MENU, then press ▲ several times until
is displayed and
confirm.
MENU/ENTER: to enter a menu/confirm the data entry.
▲: to modify the displayed figure or menu item.
◄: to select a new figure or modify the displayed menu item.
ESC: to cancel and return to the previous menu.
MINIMUM WEIGHT
(from 0 to max full scale; default: 10): minimum weight, value at which the scale is considered
empty. Batching start is only allowed if the weight is lower than this value, during the unloading
phase the CYCLE END contact will be opened when the weight reaches this value and after the
safe emptying time is over.
MAXIMUM WEIGHT
(from 0 to max full scale; default: 0): settable and displayable maximum weight. If the
displayed weight exceeds the maximum weight by 9 divisions, the
message is displayed; if
in the formulas programming the weight value set is greater than this value, the
message is
displayed and the value will not be stored.
By setting 0, the function is disabled.
SAFE EMPTYING TIME
(from 0.0 to max 999.9 seconds; default 5.0): time that is necessary for a perfect emptying of
the scale. The instrument waits for this time during the unloading phase (CYCLE END closed), after
reaching the minimum weight and before opening the CYCLE END contact to obtain a perfect
emptying of the scale.
WAITING TIME
(from 0.0 to max 999.9 seconds; default 5.0): time elapsing between the SET end batching
and the CYCLE END closing to allow the weight to get steady. This waiting time is only required if
the automatic fall is programmed and/or consumption is enabled and/or printing is enabled and/or a
tolerance value has been programmed and/or confirmation from PC is enabled and/or USB option is
present and/or DATIPC option is present.