© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
14
1) Contacts, proximity switches, programmable controller outputs,
etc.
-
TEXT DISPLAY WITHOUT PROGRAMMABLE CONTROLLER
Flat cabel LCA 030, LCA 031
UNIVERSAL ADAPTER LCA 024
1)
Programmable Controller connection
+24 V=
5.1 UNIVERSAL ADAPTER LCA 024/025
When text display LCA 042 can not be driven by a pro-
grammable controller, for example when used with con-
ventional relay controllers, we recommend the use of the
universal adapter LCA 024.
Up to 64 limit switches, proximity switches, relays and
electronic outputs can be connected to the LCA 024. The
text display and the universal adapter are organized in
such a way that a “logical 1” on terminal 1 of the LCA 024
invokes message 01 in the text display. The same applies
for inputs 3...64.
The terminal number corresponds to
the message number. If logical 1 is present on
several inputs simultaneously
, their messages can be
displayed cyclically or invoked one after the other by
means of a key.
If 64 message inputs are not enough, an extension up
to 127 inputs is possible using universal adapter expander
LCA 025.
For more detailed information see the description of
the universal adapter.