© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
20
max. thickness of material 5 mm
247 +0.5 mm
67 +0.5 mm
FRONT PANEL CUTOUT
254 mm
58 mm
74 mm
72 mm
LCA viewed from front
LCA viewed from above
LCA viewed from side
LCA viewed from rear
rubber seal
LCA 010 connection
Prog. Cont. connection
LCA 014 connection
message texts
EPROM
2.3 SPECIFICATIONS
A high degree of immunity
1
to interference and of
electrical protection (IP 65) ensure correct functioning,
even in rough industrial environments.
TECHNICAL DATA
Operating Voltage
19 ... 33
V
Power consumption
8
W
Signal voltage
19 ... 33
V=
Signal current (U
B
= 24V)
9
mA
Display
flourescent
Characters per line
40
Character depiction
5 x 7
matrix
Character height
7
mm
Character set
ASCII
Message invocation
BCD / BINÄR
1 AKTIV / Ø AKTIV
Messages
max 200
Messages text memory
RAM/EPROM
External variables
max. 40 characters
Operating temperature
0 ... 50
°
C
Storage temperature
-25 ... 70
°
C
Connections
plug-type
Electrical protection
IP 65
Weight
approx. 1000
g
Dimensions
see dim. drawing
Installation is simple, all that is needed is a cutout in the
front panel. The rugged housing consists of two parts
which are separated for installation.
1) In order to ensure the maximum degree of immunity to
interference, the keyboard LCA 010 and the EPROM programmer
should not remain connected during operation of the text display.