11.3
Refrigerant and filling quantity
The device contains fluorinated greenhouse gases.
Table 19
Unit
VC 1200
VC 2000
VC 1200 W
VC 2000 W
Refrigerant
---
R-449A
R-449A
R-449A
R-449A
Maximum filling weight
kg
0.50
0.58
0.50
0.58
GWP
(100a)
*
---
1397
1397
1397
1397
CO
2
equivalent
t
0.70
0.81
0.70
0.81
Table 20
Unit
VC 3000
VC 5000
VC 3000 W
VC 5000 W
Refrigerant
---
R-449A
R-449A
R-449A
R-449A
Maximum filling weight
kg
0.95
1.10
0.95
1.10
GWP
(100a)
*
---
1397
1397
1397
1397
CO
2
equivalent
t
1.33
1.54
1.33
1.54
Table 21
Unit
VC 7000
VC 10000
VC 7000 W VC 10000 W
Refrigerant
---
R-452A
R-452A
R-452A
R-452A
Maximum filling weight
kg
2.0
2.0
2.0
2.0
GWP
(100a)
*
---
2140
2140
2140
2140
CO
2
equivalent
t
4.28
4.28
4.28
4.28
Global Warming Potential (GWP), CO
2
comparison = 1.0
* Time frame 100 years - according to IPCC IV
11.4
Filling volume and characteristics of the pumps
Table 22
Device
Maximum/minimum filling
volume
Pump connection
Drain tap
L
---
---
VC 1200 (W)
15/8
G
¾
(15), ¾" hose nozzle
G
½"
VC 2000 (W)
15/8
G
¾
(15), ¾" hose nozzle
G
½"
V08
Variocool
85 / 97
Summary of Contents for VC 1200
Page 38: ...Fig 13 Menu structure part 2 Menu structure for Graph Clock and Standby V08 Variocool 38 97 ...
Page 98: ......
Page 99: ......