![Lattice Semiconductor mVision AR0234 User Manual Download Page 12](http://html1.mh-extra.com/html/lattice-semiconductor/mvision-ar0234/mvision-ar0234_user-manual_3849570012.webp)
Lattice mVision AR0234 Sensor Board
User Guide
© 2021-2022 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at
All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice.
12
FPGA-UG-02124-1.1
Figure 4.3. CrossLink Programming Status
7.
Select ECP5UM for Device Family, LFE5UM-85F for Device, Fast Program for Operation, and
mVision_ISP_1080p_impl1.bit for File Name as shown in
Figure 4.4. ECP5 Programming Setup
8.
Click the Program button to program and check the status.
Figure 4.5. ECP5 Programming Status
9.
Connect the HDMI monitor to the board using the HDMI cable.
10.
Toggle the SW3 (SYS_RST) button on the Crosslink VIP Bridge Board. The sensor-captured video is displayed on the