15
Advanced settings, cont’d
Temperature limits
Set
Min./Max.
settable
temperature limits
Overheat limit
Set
Overheat air
limit if floor sensor has been installed
Control Period
Set between
10 – 60 mins.
Control period checks the difference in the current measured temperature and the set
temperature in a proportional integral algorithm to maintain a steady temperature.
About
Details about the STRATA_HEAT™ Smart LCD Thermostat’s
current firmware, MAC address and Wi-Fi
connection information.
Display is blank
Brightness
1. Check that the standby brightness is not set to Off.
Power
2.
(Electrician Required)
Electrician required to verify
power is going to the STRATA_HEAT Smart LCD Thermostat
and that it is correctly wired.
ER1/ER2
Sensor Error
(Electrician Required)
Electrician required to verify that
the floor sensor has been wired correctly. If it is correctly
wired the electrician will need to check the resistance of the
floor sensor using a multi meter. For temperatures between
68°F – 86°F (20°C – 30°C) the resistance of the floor
sensor should measure between 8K ohms and 12K ohms.
If the electrician finds a fault, and the STRATA_HEAT Smart
LCD Thermostat is in the room to be heated then it can be
set into “Air Mode”.
To set into “Air Mode”, go to Sensors & Application in
Advanced Settings and switch the probe off.
Heating is coming
on earlier than
programmed times
Adaptive learning
(Early Start) On
Adaptive learning will use the
historic heating/cooling rates
for the time of day, historic external temperatures and the
forecast external temperatures, to work out the heating
start time in order to reach the comfort time at the start of
the comfort period. It will only work in Program Mode.
Cannot to set above
a certain temperature
Floor Type
Temperature Limits
Delicate floor coverings need to have their temperatures
limited. If the finished floor is set for wood, laminate,
vinyl etc. you are unable to set the temperature above
81°F (27°C).
Wi-Fi Error Symbol
Wi-Fi not setup
If you have not done so, download the MySTRATA_HEAT
App, go to Settings and Network setup and follow the on
screen instructions to connect to a Wi-Fi Network.
Wi-Fi disconnected
Follow the step above to try and to re–connect to the
Wi-Fi Network.
If the STRATA_HEAT Smart LCD Thermostat still fails to
connect, see Wi-Fi Troubleshooting.
Clock Sync Icon
Time and Date
not set
Connect the STRATA_HEAT Smart LCD Thermostat to a
Wi-Fi network or alternatively set the time and date from
the settings menu.
Advanced Settings
Troubleshooting