12
5.3.2 Lanyard
Always use an energy absorbing lanyard or retractable type fall arrestor that comply with relevant standards
within the country of use.
Where a work positioning lanyard is used, it should conform to the relevant standard (such as EN 358), and
should only be used in conjunction with a fall arrest lanyard (See Section 7.3).
5.3.3 Connectors
Connectors must conform to EN 362 and be securely locked to prevent opening.
WARNING! Incompatible components can lead to connectors
accidentally disengaging.
6 Inspection
The Latchways PRD has been specifically designed as a user friendly device, incorporating a range of
features to aid pre-use checks and on-site periodic examination, and wherever possible minimise the need
to return the device to Latchways or authorised agent.
6.1 Pre-use checks
These are the detailed descent device and harness checks that should be carried out by the user before
each use.
s4HOROUGHLYINSPECTALLEQUIPMENTANDCOMPONENTSBEFOREEACHUSE
s.OREPAIRSMODIlCATIONSORALTERATIONSARETOBECARRIEDOUTONTHE02$
UK
Personal Rescue Device
User Instruction Manual
6.1.1 Descent device/line
Figure 4
Figure 5
s )NSPECTTHE$RINGCONNECTORFORSIGNSOFDAMAGEEXCESSIVEWEARDISTORTION
corrosion or cracking.
s
Ensure that the descent line is not paid out of the device, this would indicate that
a descent has occurred (See Figure 4).
If descent line is paid out do not use.
Remove the PRD from service and refer to Latchways or authorised agent.
s /PENTHEBACKPACKCONTAININGTHEDESCENTDEVICE
(See Figure 5).
s )NSPECTTHEGENERALCONDITIONOFTHEDESCENTDEVICEFORSIGNSOFDAMAGEOR
corrosion. If damage is apparent do not use. Remove the PRD from service and
refer to Latchways or authorised agent.