5. Pre-use checks
Always fully inspect the following:
System tension
Depending on the type of system tension indicator fitted this can be checked using 1 of 2 methods.
Tenser disk
– This is generally located at the bottom of the system on the bottom anchor, when the system is
correctly tensioned, the disc will spin freely with up to 2 mm of vertical movement. (On some installations the
tenser disc may be located at the top of the system).
Visual tension indicator
– This component allows the user to check the system tension in situations where it
is impractical to reach a tension indicator disc from a position of safety.
If a fault is identified with system tension the system shall not be used and the issue raised with site supervision.