08
2. The maintenance of salt chlorinator
2.1 The maintenance of the electrolysis cell
To ensure the smooth operation of the salt chlorinator, the electrolysis cell should
be checked every three
after cleaning the
months or
filter, whichever comes first.
Follow the steps below to complete the check:
A
.
Before removing the electrolysis cell, close the inlet and output valve
after
shut
dowm
the salt chlorinator for 5 – 10 minutes.
B
.
After removal of the electrolysis cell, check to see if there are flake-like sediments,
debris, light colored layering in the inner surface. Wash with clean water.
C
.
If there are white calcified substance on the titanium plate. Submerge the titanium
plate into 4:1 water
hydrochloric acid
to remove the calcified
and
solution
substance. Please wear rubber gloves and eye protection for safety.
D
.
If there are major sediments that cannot be removed on one’s own, please contact
the seller for professional suggestion.
1
.
5 Decrease the concentration of salt
The only way to decrease the concentration of salt is to drain a part of the pool’s
water and replacing it with fresh water.
1
.
6 In
order
to
reduce
the
loss
of
chlorine
by
the
UV
radiating
on
outdoor
pool
water
,
dose
Cyanuric
acid
of
20—100mg
/
L
as
chlorine
stabilizer
.