05
①
②
③
④
⑤
⑥
⑦
⑧
Control panel operation manual
Control panel indication diagram
①
LED monitor (displays the water temperature under
normal operation, displays the corresponding error
code when problem occures).
②
Level indication light ( 1 light represent level 1, 2
light represents level
2 …… 5 lights represents 5
level).
③
Level addition button
④
Boost indication light
⑤
“Boost” button
⑥
Level reduction button
⑦
Operation indication light
⑧
Start/stop button
ERROR CODE AND CORRESPONDING SOLUTIONS
5
Error
code
Reason of error
Remark
Solution
E1
E2
E3
E4
The temperature of the
cooling fin is too high
The water temperature
is beyond the normal
range
No water
The salt concentration
is too high
E5
♦
N o r m a l t e m p e r a t u r e
should be below 65 C
♦
The malfunction must
be removed manually
♦
The normal range of
operating temperature
is 10~45 degrees Celsius
♦
Normal operation
requires enough water
in the chlorinator
♦
Normal salt concentration
is
ppm
range
2700- 4500
♦
First check if E6 error code is p r e s e n c e , i f i t
i s , c h e c k i f t h e temperature sensor is attached.
If it is, please change the sensor;
♦
If E6 error code is not presence, please check the
hardware circuit
♦
First check if E7 error code is presence, if it
is , check if the temperature sensor is attached.
If it is, please change the sensor;
♦
If E7 error code is not presence. Please check
that the water is within the range of operational
temperature.
♦
First, check if the water level detector is attached.
If it is , check if water is lacking or air was present.
If water is presence, wash the water level detector.
♦
First use a salinity meter to check the salt concentration
in the pool.
if the salt concentration level in the pool
is above
ppm, drain part of the pool and replace
4500
with fresh water. When the salinity level of the pool
reaches the normal operation salinity level, the
error code should disappear. And the machine should
function again.
♦
First use a salinity meter to check the salt concentration
in the pool. if the salt concentration level in the pool
is below
ppm, add salt to the
. When the
2700
pool
salinity level of the pool reaches the normal operation
salinity level, the error c o d e s h o u l d disa p p e a r.
And the machine should function again.
04
5
.
By pressing the “+” or “-” button, users can adjust the chlorine concentration level
to need; users can choose from 1~5 level, 1 level is the smallest and 5 level is the
highest. The higher the level, the higher the concentration of chlorine is produced.
6
.
If the rate of chlorine production needs to be accelerated, press the “Boost”
button. The Chlorinator would operate at maximum capacity for 8 hours, then
return to the original preset state.
3
.
Before
operation
,
make
sure
that
the
salt
concentration
of
pool
water
is
in
the
normal operating range
,
otherwise
it
can
reduce
the
service life
of
Titanium
polar
.
4
.
C l o s e t h e e l e c t r i c i t y l e a k a g e s w i t c h t o a c t i v a t e t h e
P r e s s the
d i s p l a y.
Operate button, the operation light wound
turn
from
red
to
green, and
STANDBY/ON
the chlorinator would start operating. Note: the chlorinator can only function when
the water level detector detects the presence of enough
water
flow.
7. Parameters check: press the “ ”
acceleration key multiple times while the
chlorinator is off to look up different parameters below:
①
Temperature of the interior of chlorinator
②
Water temperature
③
Input voltage
④
Version number
⑤
Time period of continuous operation; The system automatically exits the
inquiry after 3 seconds.
NOTE
The chlorinator is preset to continuous operation for 12 hours; if 24 hour non-stop
operation is needed, the time setting for continuous operation would have to be
set at 24; the system automatically exits the setting after 3 seconds.
9
.
When the chlorinator reports a malfunction or warning,
“ ”
acceleration
press
key
to clear it and resume to nomal operation.
8
.
Time setting for continuous operation: press the “ ”acceleration key 5 times
while the machine is off to display the time period of continuous operation.
Change the time periods of continuous operation by pressing “+” or “-”. The
length of time range from 1- 24 hours. For example, if the value is set at 12,
the chlorinator would operate for 12 hours ( then turn off ) after it has been
turned on. The chlorinator will stop for 12 hours and turn on for 12 hours again
following this cycle.
o
The salt concentration
is too low
♦
Normal salt concentration
is
ppm
range
2700- 4500