background image

Page 

9

EC-2502

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

10. DESCRIPTION OF TERMINALS

AC1

el. cassette supply 14,5V AC

K1   (VS)*

 

ext. panel supply (stabilized v12V)

AC2

  el. cassette supply 14,5V AC

K2   (T)*

 

digital data from/to ext. panel

AC3

  electro-catch supply 12V AC

K3   (GS)*

 

digital mass

AC4

  electro-catch supply 12V AC

K4   (SP)*

 

loudspeaker

GP

 

mass of non-stabilized voltage

K5   (GA)*

 

analogue mass

VP

 

non-stabilized voltage output

K6   (MC)*

 

microphone

GZA

mass of electro-catch supply

L+

 

uniphone line + (if works as EC-2502U)

VZA

electro-catch supply

communication line between cassette H and U

KZ

output of key switching on el.-catch

(if works as EC-2502H)

VZ

electro-catch supply

L-

 

uniphone line - (if works as EC-2502U)

GZ

mass of key switching on el.-catch

LM

 

master line (to connect main electronic cassette)

GS'

 

mass of stabilized voltage

NC

 

free terminals (e.g. to connect segments of wire)

VS'

 

stabilized v12V

X

 

input of electronic key reader

PR

 

door opening pushbutton

B+

 

connection of accumulator (+)

CS

 

selection of video signal source

B-

 

connection of accumulator (-)

(XX)*

description on PCB

Figure 5: Electronic cassette block diagram

11. DIMENSIONS OF ELEMENTS

Figure 6: Dimensions of electronic cassette EC-2502

demagnetizing

ZT1

A

B

AC1

AC2

AC3

AC4

VP

VS

GS
GP

1,85 A

VZA

GZA

GA

VZ

KZ

GZ

el.catch

lock

+12V

stabilizer

L+

L-

MC

SP

PR

CS

T

GD

X

NC

NC

JP3

switching

key

uP

All manuals and user guides at all-guides.com

Summary of Contents for EC-2502

Page 1: ...DIGITAL ENTRY PHONE SYSTEM INSTALLATION SERVICE AND PROGRAMMING MANUAL OF ELECTRONIC CASSETTE EC 2502 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ion of testing the electro catch control frequency after changing the Fry parameter Increased entrance preview time after the entry of coded lock code Added keypad blocking function during RFID readin...

Page 3: ...supply adapter is mounted supply from power network should be routed Electronic cassette casing is fixed to the base by means of two screws Wire ends from feeding transformer should be wound on the s...

Page 4: ...t on joint J3 and operation frequency parameter FrY should be set on 0 see figure 2 In case electro catch is used jumper should be removed from joint J3 Figure 2 Selection of electro catch or electrom...

Page 5: ...nt NbL 1 1 0 0 1 1 1 0 0 1 1 0 0 1 1 U H U H U H U H U H U U U U U H U H U H U H U H Sound signal of sign selected from the keyboard Multitone signaling of sign selected from the keyboard Duration of...

Page 6: ...the apartment Addition of key with assigned to the apartment Addition of key on the selected item in memory Deleting the key Deleting the key assigned to the apartment Deleting the key recorded in the...

Page 7: ...s configured as EC 2502 H after finishing of this operation the cassette will still operate in this mode Pushbutton RESET is used for momentary stopping the operation of a processor Its pressing makes...

Page 8: ...nd supplier Subordinate entrances should be connected in such a way as if entry phone CD 2502 line L L was installed at the main entrance If CD 3100 is connected with CD 2501 mode with building number...

Page 9: ...ne between cassette H and U KZ output of key switching on el catch if works as EC 2502H VZ electro catch supply L uniphone line if works as EC 2502U GZ mass of key switching on el catch LM master line...

Page 10: ...n AC2 AC1 CP xxxx 12 V AC 1 A Brown Brown K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VP GP AC4 AC3 C C EC 2502 U 230 V AC 14 5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brown Brown L L K...

Page 11: ...SY UTP LAN T11 XzTKMXpw Clamps Distance CP EC 15m 30m K1 K4 K1 K4 0 5mm 2x 0 5mm K2 K6 K2 K6 0 5mm 0 5mm K3 K3 3x 0 5mm 5x 0 5mm K5 K5 2x 0 5mm 2x 0 5mm X GX X GS 0 5mm 0 5mm Note In panels 250xxR GX...

Page 12: ...nsiderably contributes to the protection of human health and life as well as protection of natural environment Return of packaging materials for the material recycling saves raw materials and reduces...

Reviews: