background image

to another distributor

or change-over

switch

Page 

10

LM

L+

L-

K6

K5

K4

K2

K3

K1

X

GS’

NC

1

NC2

X-

X+

C2-

C2+

V+

G

CS

C

1

-

C

1

+

LM

LM

L

-

NOTE!

Terminals GZ, GZA and VZ, VZA
are connected permanently
inside electronic cassette.

!

EC-2502

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

CVR-x

EC-2502/H

230 V AC

14,5 V AC

0,8 A

White

Brown

AC2

AC1

CP-xxxx

12 V AC

1 A

Brown

Brown

K6

K5

K4

K2

K3

K1

X

GX

GZ

VZ

KZ

GZA

VZA

VP

GP

AC4

AC3

C-

C+

EC-2502/U

230 V AC

14,5 V AC

0,8 A

White

Brown

AC2

AC1

CP-xxxx

12 V AC

1 A

AC4

AC3

Brown

Brown

L+

L-

K6

K5

K4

K2

K3

K1

X

GS’

K6

K5

K4

K2

K3

K1

X

GX

GZ

VZ

KZ

GZA

VZA

VS’

GS’

NC1

NC2

C-

C+

CS

CVP-1

MAIN ENTRANCE

SUBORDINA

TE ENTRANCE

Electro-catch

MON1
MON2
MON3
MON4

power supply

of electronic

cassette

power supply

of electronic

cassette

Electro-catch

Figure 7: Entry phone CD-2502 video - multi entrance system

12. SELECTION OF WIRES AND CONNECTION DIAGRAMS

C-

C+

L+

L-

All manuals and user guides at all-guides.com

Summary of Contents for EC-2502

Page 1: ...DIGITAL ENTRY PHONE SYSTEM INSTALLATION SERVICE AND PROGRAMMING MANUAL OF ELECTRONIC CASSETTE EC 2502 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ion of testing the electro catch control frequency after changing the Fry parameter Increased entrance preview time after the entry of coded lock code Added keypad blocking function during RFID readin...

Page 3: ...supply adapter is mounted supply from power network should be routed Electronic cassette casing is fixed to the base by means of two screws Wire ends from feeding transformer should be wound on the s...

Page 4: ...t on joint J3 and operation frequency parameter FrY should be set on 0 see figure 2 In case electro catch is used jumper should be removed from joint J3 Figure 2 Selection of electro catch or electrom...

Page 5: ...nt NbL 1 1 0 0 1 1 1 0 0 1 1 0 0 1 1 U H U H U H U H U H U U U U U H U H U H U H U H Sound signal of sign selected from the keyboard Multitone signaling of sign selected from the keyboard Duration of...

Page 6: ...the apartment Addition of key with assigned to the apartment Addition of key on the selected item in memory Deleting the key Deleting the key assigned to the apartment Deleting the key recorded in the...

Page 7: ...s configured as EC 2502 H after finishing of this operation the cassette will still operate in this mode Pushbutton RESET is used for momentary stopping the operation of a processor Its pressing makes...

Page 8: ...nd supplier Subordinate entrances should be connected in such a way as if entry phone CD 2502 line L L was installed at the main entrance If CD 3100 is connected with CD 2501 mode with building number...

Page 9: ...ne between cassette H and U KZ output of key switching on el catch if works as EC 2502H VZ electro catch supply L uniphone line if works as EC 2502U GZ mass of key switching on el catch LM master line...

Page 10: ...n AC2 AC1 CP xxxx 12 V AC 1 A Brown Brown K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VP GP AC4 AC3 C C EC 2502 U 230 V AC 14 5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brown Brown L L K...

Page 11: ...SY UTP LAN T11 XzTKMXpw Clamps Distance CP EC 15m 30m K1 K4 K1 K4 0 5mm 2x 0 5mm K2 K6 K2 K6 0 5mm 0 5mm K3 K3 3x 0 5mm 5x 0 5mm K5 K5 2x 0 5mm 2x 0 5mm X GX X GS 0 5mm 0 5mm Note In panels 250xxR GX...

Page 12: ...nsiderably contributes to the protection of human health and life as well as protection of natural environment Return of packaging materials for the material recycling saves raw materials and reduces...

Reviews: