Manual: RS 800 G US, RS 800 RGY US, RS 1000 RGB US, RS 2300 RGB US RS-2700 RGB US 

6 / 9 

Revision  Jun-13 

Change scanner 

Unscrew UK M6 screws and disconnect signal cable. 
Loosen M4 x 10 screw and remove galvo.  

Insert galvo, reconnect and fix signal cable. 
Rotate galvo to centre projection. Fix galvo. 

Adjustable mirror mounts 

RS-800RGY, RS 1000/2300 RGB: Loosen setscrews, 
then adjust with X/Y adjustable screws. Make sure 

beam is centered on scanner mirrors. Adjust Z-screw 
simultaneously Tighten setscrews. 

When combining beams (RGY/RGB laser), first make sure 
the beams are (roughly) on the same spot on the 
mirrors/dichros. Then use a test pattern (e.g. rectangle) to 
do fine adjustment. For adjustments, always turn output 
power down (if possible). 

Troubleshooting 

Problem 

Possible reason 

Damaged part 

Replacement 

No power 

Fuse blown 

Fuse 

09-00-3001-01 

Power supply defective 

+-24V 

16-03-0039-00 

Music mode not working 

Microphone defective 

Microphone 

16-03-0001-00 

Control board defective 

Control board 

26-2A-LT12V2-00 

Potentiometer defective 

Potentiometer 

04-03-0104-01 

CPU defective 

IC 

00-89C516RD-00 

 

 

X and/or Y axis no deflection 

 

Scanner defective 

Galvo 

15-01-2215-00 

CPU defective 

IC 

00-89C516RD-00 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

Scanner driver board defective 

Scanner driver board  

26-2A-6800A-00 

 
 

Laser dark or dim 

Lenses / mirrors dirty 

Clean with alcohol 

 

Laser diode defective 

Laser diode 

Inquire 

Control board defective 

Control board 

26-2A-LT12V2-00 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 

 

 

No output 

Configuration / wrong mode 

Check configuration (see 

paragraph control panel) 

 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

Display board defective 

Display 

26-2A-YX2012DI-00 

Pins 4 and 17 of the ILDA signal not 

connected 

See below 

 

Laser does not switch to ILDA mode:  

 

The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface manual 

 

The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17. 

 

Use an adapter, that connects pins 4 and 17. 

ILDA signal 

Pin out of the standard ILDA signal: 

1 Scanner X+  

-5V..+5V 

14 X- 

+5V..-5V 

2 Scanner Y+  

-5V..+5V 

15 Y- 

+5V..-5V 

3 Intensity/B 

0V..+2.5V 

16 Intensity/Blanking- 

0..-2.5V 

4 Interlock A 

 

17 Interlock B 

5 Red+  

0..+2.5V 

18 Red- 

0..-2.5V 

6 Green+  

0..+2.5V 

19 Green- 

0..-2.5V 

7 Blue+  

0..+2.5V 

20 Blue- 

0..-2.5V 

8 – 12 Not used 

 

23-24 Not used 

13 S5V, max. 20 mA 

25 GND Signal ground

 

Summary of Contents for RS 800 G US

Page 1: ...RS 800 G US RS 800 RGY US RS 1000 RGB US RS 2300 RGB US RS 2300 RGB US Manual Read carefully before using this device ...

Page 2: ...ed particularly with respect to how they will reach the audience If direct audience scanning is desired then the laser energy in the effects needs to be considered to decide if the effects are safe for direct viewing Always ensure that the maximum permissible exposure MPE is not exceeded in the area accessible to the public So install the laser in such a way that minimum distances and heights ensu...

Page 3: ...please contact your dealer When returning laser to dealer manufacturer always use original packaging Maintenance should be performed every 15 day period See cleaning further down To ensure maximum lifetime of the laser Don t overheat the laser Always ensure good ventilation Don t have stage lights especially moving heads directed towards the laser Regularly clean the fans and the interior from dus...

Page 4: ... first reduce the scanangle image size Otherwise you may damage the scanners When using with different scanspeed scanangle readjustment of the scanner drivers may be necessary if in doubt contact your dealer DMX mode Channel DMX512 value Function 1 blue 0 63 Auto Music Mode Ch 1 2 valid 64 127 Auto mode Ch 1 2 valid 128 191 Music edit mode All channels valid 192 255 Manual mode All channels valid ...

Page 5: ...e direction to minimize the effect of scratches Mirrors need cleaning when a halo is noticeable around the beam or an unusual high amount of diffuse light can be seen inside the device When fog fluid condenses in the device clean all traces and rearrange the position of fazer and or laser Technical specifications Output power at the laser RS 800 G min 550mW max 800mW 550mW 532nm green RS 800 RGY m...

Page 6: ...vo 15 01 2215 00 CPU defective IC 00 89C516RD 00 Control board defective Control PCB 26 2A LT12V2 00 Power supply defective 24V 16 03 0039 00 Scanner driver board defective Scanner driver board 26 2A 6800A 00 Laser dark or dim Lenses mirrors dirty Clean with alcohol Laser diode defective Laser diode Inquire Control board defective Control board 26 2A LT12V2 00 Configuration wrong mode Check config...

Page 7: ...d to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Laserworld cannot be made liable for damages caused by incorrect installations and unskilled operation For service contact your dealer or Laserworld Only use Laserworld spare parts Data subject to change without notice Errors and omissions expected Te...

Page 8: ...aser apertures The positions of the warning labels EN 60825 1 are Warning Logotype Position 1 Noninterlocked Protective Housing Label Position 1 Aperture Label Position 2 Laser Radiation Emission Indicator Position 3 and on remote control unit Laser aperture laser radiation will be emitted through the window at position 4 1 2 3 4 ...

Page 9: ...il Oberhofen SWITZERLAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil Oberhofen SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau www laserworld com info laserworld com representative according to EMVG Cleantech Europe GmbH Managing Director Thomas Schulze Fürkhofstr 5 81927 München DE ...