Manual: RS 800 G US, RS 800 RGY US, RS 1000 RGB US, RS 2300 RGB US RS-2700 RGB US
6 / 9
Revision Jun-13
Change scanner
Unscrew UK M6 screws and disconnect signal cable.
Loosen M4 x 10 screw and remove galvo.
Insert galvo, reconnect and fix signal cable.
Rotate galvo to centre projection. Fix galvo.
Adjustable mirror mounts
RS-800RGY, RS 1000/2300 RGB: Loosen setscrews,
then adjust with X/Y adjustable screws. Make sure
beam is centered on scanner mirrors. Adjust Z-screw
simultaneously Tighten setscrews.
When combining beams (RGY/RGB laser), first make sure
the beams are (roughly) on the same spot on the
mirrors/dichros. Then use a test pattern (e.g. rectangle) to
do fine adjustment. For adjustments, always turn output
power down (if possible).
Troubleshooting
Problem
Possible reason
Damaged part
Replacement
No power
Fuse blown
Fuse
09-00-3001-01
Power supply defective
+-24V
16-03-0039-00
Music mode not working
Microphone defective
Microphone
16-03-0001-00
Control board defective
Control board
26-2A-LT12V2-00
Potentiometer defective
Potentiometer
04-03-0104-01
CPU defective
IC
00-89C516RD-00
X and/or Y axis no deflection
Scanner defective
Galvo
15-01-2215-00
CPU defective
IC
00-89C516RD-00
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Scanner driver board defective
Scanner driver board
26-2A-6800A-00
Laser dark or dim
Lenses / mirrors dirty
Clean with alcohol
Laser diode defective
Laser diode
Inquire
Control board defective
Control board
26-2A-LT12V2-00
Configuration / wrong mode
Check configuration (see
paragraph control panel)
No output
Configuration / wrong mode
Check configuration (see
paragraph control panel)
Control board defective
Control PCB
26-2A-LT12V2-00
Power supply defective
+-24V
16-03-0039-00
Display board defective
Display
26-2A-YX2012DI-00
Pins 4 and 17 of the ILDA signal not
connected
See below
Laser does not switch to ILDA mode:
The interface does not connect pins 4 and 17 (Interlock) of the ILDA signal. See interface manual
The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
Use an adapter, that connects pins 4 and 17.
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+
-5V..+5V
14 X-
+5V..-5V
2 Scanner Y+
-5V..+5V
15 Y-
+5V..-5V
3 Intensity/B
0V..+2.5V
16 Intensity/Blanking-
0..-2.5V
4 Interlock A
17 Interlock B
5 Red+
0..+2.5V
18 Red-
0..-2.5V
6 Green+
0..+2.5V
19 Green-
0..-2.5V
7 Blue+
0..+2.5V
20 Blue-
0..-2.5V
8 – 12 Not used
23-24 Not used
13 S5V, max. 20 mA
25 GND Signal ground