Final statement
Product and package leaving warehouse without faults. Users have to follow the local safety
regulations and warnings of this manual. Damages through inappropriate use do not unterlie
the sphere of influence of manufacturer or dealer. Therefore no liability or warranty will be
taken over. We cannot inform you in case of changes of this manual. If you have any questions,
please contact your dealer.
For service please contact your dealer or Laserworld. Please use only spare parts of Laserworld.
Subject to change without notice. Because of the vast amount of data we cannot guarantee
any correctness of given information.
Laserworld (Switzerland) AG
Kreuzlingerstrasse 5
8574 Lengwil-Oberhofen
SWITZERLAND
Registered office:
8574 Lengwil-Oberhofen / Switzerland
Company number: CH-440.3.020.548-6
Commercial Registry Kanton Thurgau
CEO: Martin Werner
VAT no. (Switzerland): 683 180
UID (Switzerland): CHE-113.954.889
VAT no. (Germany): DE 258030001
WEEE-Reg.-No. (Germany): DE 90759352
www.laserworld.com
representative according to EMVG:
Cleantech Europe GmbH
Managing Director: Thomas Schulze
Fürkhofstr. 5
81927 München / GERMANY
6. Interlock / Safety
There is a Interlock-/Safety-LED on the rear side of the device. If this LED lights up,
one of the following cases stopped the beam output:
1. For a short time after switching on the device (self test). During the initial startup
time of a few seconds there is no output for safety reasons.
2. The device is connected to the power supply but not to an ILDA connection.
3. The interlock system of the device will block output if there is no connection to
pin 7 and 14 of the ILDA signal line.
4. The scan fail safety will block output if there is a failure at the scanning system.
5. If the beam block safety is activated, the system does not allow to project single
beams or very small patterns. This is also indicated by the safety LED.
7. Safety Presets
By default there are following safety presets in the device:
- Scan fail safety (accord. IEC 60825-3):
active
-
beam
block
safety inactive
- ILDA-Interlock processing (pins 7 + 14)
active
The safety options can be adjusted at the scanner board. Please see the manuals on
Laserworld website for details.
7. Turn off
To turn off the device disconnect the power cable from the mains.
Important Note:
Operate scanners/galvos only at appropriate speed according to the res-
pecting scan angle. Too high scan speed can damage the scanning system.