6. MAINTENANCE 

 

Maintenance should be perfomed ervery 15-day period, by using a sponge wich is 
dipped with alcohol, rather than wet cloth or other chemical liquid, to clean the 
mirror. 

Always disconnect from the mains when the device is not in use or before cleaning it. 
 
There are no serviceable parts inside the device. Maintenance and service operations 
are only to be carried out by authorized dealers. 
 

Never look directly into the light source. 

 

Always disconnect from the mains when the device is not in use or before 
cleaning it. 

 

 

7. TECHNICAL SPECIFICATIONS 

 

Power supply:

 AC 220V-240V, 50/60 Hz 

DMX 512: 

 10 channels 

Ambient temperature:

 -10°C – +35°C 

Power consumption:

 40 W 

Working mode:

 automatic, music active, DMX512 

Optical power:

  

green: ca. 100mW / 532nm 

red: ca. 300mW / 650nm 

Laser classification:

 3b 

Weight:

 5 kg 

Dimensions:

 285 x 160 x 230 mm 

 

 

 
PLEASE NOTE 
 

This device has left our premises in absolutely perfect condition. In order to maintain 
this condition and to ensure a safe operation, it is absolutely necessary for the user 
to follow the safety instructions and warning notes written in this user manual. 

Laserworld cannot be made liable for damages caused by incorrect installations and 
unskilled operation! 

Summary of Contents for EL-400RGY

Page 1: ...EL 400RGY USER MANUAL Please read this manual carefully before use...

Page 2: ...ts Page 1 SAFETY INSTRUCTIONS 3 2 OPERATING DETERMINATIONS 4 3 AUTO MUSIC MODE 5 4 OPERATION WITH DMX 5 5 DMX CHANNELS 6 6 MAINTENANCE 7 7 TECHNICAL SPECIFICATIONS 7 Checking Parts Please check if the...

Page 3: ...on is only allowed if it is controlled by a skilled and well trained operator Never leave this device running unattended and keep it away from children and unauthorized persons 2 Keep away from heater...

Page 4: ...gned for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects 10 In some countries the operator must notify the accidence insuranc...

Page 5: ...min max knob on the rear panel 4 OPERATION WITH DMX If you turn switch 10 to OFF the device is in DMX mode Set the DMX address and connect the device to a DMX controller you can then operate your EL 3...

Page 6: ...199 colours of the pattern are changed 9 Reset above 200 shortly 10 Colour effect channel 1 79 draw increasing part of the pattern 80 119 the same automaticallywith increasing speed 120 255 change co...

Page 7: ...the mains when the device is not in use or before cleaning it 7 TECHNICAL SPECIFICATIONS Power supply AC 220V 240V 50 60 Hz DMX 512 10 channels Ambient temperature 10 C 35 C Power consumption 40 W Wor...

Page 8: ...standards DIN EN 60065 2002 Furthermore the device is verified in correspondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulati...

Reviews: