Manual: DS-1000RGB, DS-1000RGB FB4
page 8 / 34
8. Operation
1. Power
Connect the power cable to the device and to the mains. Make sure that your device is
provided with the correct voltage. Wrong voltage could lead to irreparable damages.
Please find the correct voltage data in the synoptical table at the end of this manual.
It must be ensured that the device is not directed to people or inflammable objects
during installation. To start the device, connect the interlock bridge, insert the key and
switch it on, and switch the device on.
The “Emission - Laser on“ LED at the front side
of the device begins to light up when the device is ready for use.
2. ILDA in / ILDA out
The device can be controlled via ILDA control signal. There are an ILDA-in (ILDA input)
and an ILDA-out interface at the rear side of the device. Connect the laser system to the
control interface (DAC) by using an ILDA cable. Do not connect the laser to standard
parallel port at your computer, but always use an appropriate ILDA interface (usually is
sold together with the laser control software). After that you are able to control your
laser by a show laser control software (e.g. Laserworld Showeditor). Use the ILDA-out
interface to connect it to another device.
3. Fuse
There is a fuse at the rear side of the device. If the fuse should blow, please change it by
a new one. If the problems recurs, please contact your dealer or the Laserworld service
department.
4. Key Switch
There is a key switch at the back of the laser system. Please plug the key to the switch
and turn it on. The laser device only runs when the key is inserted and switched on.
Prevent misuse! Unplug the key when the laser is unattended to prevent misuse of
the system.
5. Safety Presets
This device has an integrated Scan Safety (SFS). Is the Scan Safety active (on), single
beams are prevented. If the Scan Safety is switched off
always ensure that maximum
permissible exposure (MPE) is not exceeded in areas accessible to the public or
members of staff.
6. X / Y Inversion buttons (not available for FB4 version)
Use the X-Axis, Y-Axis, and/or X-/Y-Axis buttons to invert the beams resp. patterns on the
x-axis and/or y-axis.