background image

 User manual: CS-400RGB 

Rev: 02/2009 

page4 of 8 

Keep surrounding dry and clean. T

his unit should be kept dry, do not use in the rain 

or damp and dusty environment. Projector should be put in a water-proof housing 
when operated outside.  
Operating temperature is 10~35

°C

. Let laser cool off 10minutes after 2 hours of 

operation, to ensure maximum lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 
meter. 

Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 

When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. Use a sponge with alcohol, 
rather than wet cloth or other chemical liquid, to clean the mirror. 

1.

 

 

Inbetriebnahme 

Make sure the correct voltage is used. Connect mains. Connect an emergency switch 
to the 9-pin connector on the backside (pins 1, 2). If you do not wish to connect an 
emergency switch, connect the 9-pin plug. Depending on the mode selected (see 
below), laser light should come out of the 
opening on the front panel – be careful. 

Control panel 

Microphone 

Safety switch: laser on/off 

ILDA connector 

Operating modes 

The following operating modes can be selected from the DIP switch on the backside 
of the device: 
DIP switch 1-10 

Mode 

0,0,0,0,0,0,0,0,0,0 

Music activ 

1,0,0,0,0,0,0,0,0,0 

Automatic mode / beameffects 

1,1,0,0,0,0,0,0,0,0 

Automatic mode / graphics 

x,x,x,x,x,x,x,x,x,1 

DMX 

 

Power switch: power on/off 

Remotelock: connect emergency switch. If 
no emergency switch is connected use the 
9 pin plug supplied. 

DIP switch: DMX address/mode selection 
(see below) 

DMX 512 in/out 

Music mode: sensitivity 

Summary of Contents for CS-400RGB

Page 1: ...CS 400RGB User Manual Please read this manual carefully before use...

Page 2: ...Operating modes 4 ILDA mode 5 DMX mode 5 Maintenance cleaning 6 Technical specifications 6 ILDA signal 6 Trouble shooting 7 Please note 7 EU declaration of conformity 8 Checking parts Please check if...

Page 3: ...aser series models supplied with a key switch to prevent unauthorized use warning labels and aperture labels affixed to the laser Installation safety Prior to installation and operation of the laser t...

Page 4: ...15 day period Use a sponge with alcohol rather than wet cloth or other chemical liquid to clean the mirror 1 Inbetriebnahme Make sure the correct voltage is used Connect mains Connect an emergency swi...

Page 5: ...MX mode 0 5 No beam 6 35 7 colours 36 105 Automatic colour change Slow to fast 106 175 Colour change original pattern colours 176 245 Pattern randomly coloured 2 Colour 246 255 Original pattern colour...

Page 6: ...imum 250mW 60mW 532nm green 150mW 652nm red 40mW 473nm blue Laserclass 3b Modes ILDA DMX 512 auto music active ILDA 25pin ILDA standard Sub D shaped 25pin connector Galvos 20k scanspeed DMX 512 12 cha...

Page 7: ...Interlock of the IDLA signal See interface manual The cable does not connect pins 4 and 17 Use a cable that connects pins 4 and 17 Use an adapter that connects pins 4 and 17 Please note This device ha...

Page 8: ...urthermore the device is verified in correspondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the devic...