The address is the sum of all activated numbers, see the following example settings (the white 
rectangle represents the position of the switch)

Addr 

switch 

addr 

switch 

 

 

 

65 

 

 

17 

 

 

113 

 

The laser uses 10 DMX channels, so make sure that the next device uses an address that doesn’t 
overlap with this range. E.g. when using address 1, make sure the next device uses at least address 
11. 

Channel 

function 

mode: 0-69 Laser off; 70-209 sound mode; 210-255 DMX 
mode 

patterns / animations 

strobe (with increasing speed) 

Pointspeed 

horizontal movement* 

vertical movement* 

zoom / size* 

Colour: 1-39 yellow; 40-79 red; 80-119 green; 120-159 
original pattern; 160-199 colour change 

Reset: above 200 (shortly) 

10 

Colour effect channel: 1-79 draw (increasing) part of the 
pattern; 80-119, the same, automaticallywith increasing 
speed; 120-255 change colours.

 

Please note, that not all effect channels work with every pattern. 

E.g. you can’t change 

position with dynamic patterns, or move a vertical line in y direction, etc.

 

Maintenance / cleaning 

Always disconnect from the mains when the device is not in use or before cleaning it. 
Open the device by removing the 2 upper screws on one side panel (one front and one back), then 
bend side panel outward and slide out the top. Remove any deposits of dust, especially at the fan. 
Check for condensed fog fluid inside, if so, clean and rearrange the position of laser and or hazer. 

Mirrors need cleaning, when a “halo” is noticeable around the beam, or an unusual high amount of 
diffuse light can be seen inside the device.

Clean the mirrors with window cleaner and a paper 

towel.  

Never look directly into the light source. Always disconnect from the mains when the 
device is not in use or before cleaning it. 

Summary of Contents for CL-RGY 300

Page 1: ...uirements 3 Operation 4 Sound automatic mode 4 DMX control 4 Maintenance cleaning 5 Troubleshooting 6 Technical specifications 6 Please note 6 EU Declaration of Conformity 7 Inhalt Hinweise zur Inbetr...

Page 2: ...rantielabels erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t grossen Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer e...

Page 3: ...ght source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL cause eye damage Warning labels and a...

Page 4: ...ser cool off 10 minutes after 2 hours of operation to ensure maximum lifetime for the diode Be careful not to direct stage lights toward the laser especially moving heads this can cause overheating Di...

Page 5: ...1 79 draw increasing part of the pattern 80 119 the same automaticallywith increasing speed 120 255 change colours Please note that not all effect channels work with every pattern E g you can t chang...

Page 6: ...ces aircooled DPSS laser green diode laser red Optical power at the laser max 300mW 50mW 532nm green 125mW 655nm red Beam ca 3mm 1mrad Laser class 3b Scanning system fast stepper motors ca 2 5 kpps We...

Page 7: ...ce to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispen...

Page 8: ...Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs ffnungen m ssen beim Betrieb des Geh uses frei sein 3 Benutzen Sie das Ger t nicht wenn sichtbare Besch digung...

Page 9: ...werden Hierbei werden die Muster soundgesteuert gewechselt Um die Empfindlichkeit der Musiksteuerung einzustellen benutzen sie den Einstellknopf an der R ckseite des Lasers Die Mic LED blinkt wenn di...

Page 10: ...ck mit wachsender Geschwindigkeit Bitte beachten Sie dass nicht jeder Effektkanal bei allen Mustern aktiv ist Z B kann bei dynamischen Mustern die Position nicht ge ndert werden bei der vertikalen Li...

Page 11: ...125mW 650nm rot Laserklasse 3b Betriebsmodi DMX 512 Automatik Modus Musik Modus Scannnersystem schnelle Schrittmotoren 2 5000 PPS DMX 512 10 Kan le Strahldaten ca 3mm 1mrad Stromversorgung 85 250V AC...

Page 12: ...der EN 60825 1 3 Laserschutzklassen gepr ft Nach erfolgter Installation ist eine weitere Pr fung des gesamten Aufbaus unerl sslich und muss nach den Richtlinien der EN 60825 1 3 und korrespondierende...

Reviews: