Page 10
Step 1.
To access mirror #1 you will need to remove the 3 screws from the tube access panel. By lowering this panel you will reveal the black casing which contains
mirror #1. N.B. PLEASE MAKE SURE THE LASER MACHINE IS DISCONNECTED FROM THE MAINS POWER BEFORE OPENING THE TUBE ACCESS PANEL!
Step 2.
Simply remove the three screws and loosen the fourth screw to allow you to raise the dust tube, then you will be able to remove the black dust cover off the mirror 1
housing.
.
See Below
Remove these three screws in order to
lower the laser tube access panel.
1
2
3
4
Accessing Mirror #1
Black casing
Location Of The Spirit Mirrors