Lasermet ICS-5 Wiring Manual Download Page 6

ICS Contactors Wiring Manual 

 

01518-53-000 

Page 6 of 8

 

Issue 2          13 January 2020 

 

 

Testing 

 
Testing should only be undertaken by a qualified electrical engineer. 
 
A  suitably  rated  tester  is  required  to  verify  presence/absence  of  mains  electrical  power  on  the 
contactor terminals and  any socket outlets  or load equipment  connected  to  the contactor output. 
During the tests hazardous voltages will be present inside the contactor box and on controlled outlet 
sockets  or  load  equipment.  Use  appropriately  insulated  test  equipment  and  keep  unauthorised 
personnel clear of the test area. 
 
During  testing  power  will  be  fed  to  any  connected  equipment.  Ensure  that  this  will  not  present  a 
hazard. 
 
Turn on the ICS power switch and confirm the ICS is powered (lights on front panel or power switch). 
Set the ICS ready for arming, with all monitored doors closed. Set the ICS keyswitch to ‘Enable’. The 
‘Arm’ button should be illuminated blue. 
 
Turn on the mains supply to the contactor box and confirm that voltage is present on the input line 
terminals of the contactors. 
 
Verify  that  the  contactors  are  not  energised  and  that  there  is  no  voltage  on  the  output  (load) 
terminals of the contactors, or on any outlet sockets or at the controlled device (e.g. laser) supply 
input terminals. 
 
Press the ‘Arm Laser’ button on the ICS and confirm the ‘Laser Armed’ indication is lit. 
 
Verify  that  both  contactors  are  energised  and  that  the  correct  voltage  is  present  on  all  controlled 
socket outlets and/or load equipment supply terminals. 
 
Disarm the ICS by opening a controlled door or set the keyswitch to ‘Disable’ and confirm that both 
contactors are de-energised and there is no voltage on the controlled sockets or equipment. 
 
Isolate the electrical supply to the contactor box. Remove the wire from terminal 21 of one of the 
contactors. Set the ICS keyswitch to ‘Enable’, press the ‘Arm Laser’ button and confirm that the ICS 
does not arm, the ‘Arm Laser’ button does not light, and the contactors are not energised. 
 
Replace the wire to terminal 21 of the first contactor, remove the wire from terminal 21 of the other 
contactor and repeat the test. 
 
Refit the wire to terminal 21 of the second contactor. Repeat the test and confirm that the ICS does 
arm, the ‘Laser Armed’ light is lit, and the contactors are energised. 
 
Set the ICS keyswitch to ‘Disarm’ and turn off the ICS power switch. Fit the cover to the contactor 
box and restore the supply to the contactor box. 
 
Testing is complete. 
 
 
 

Summary of Contents for ICS-5

Page 1: ...ICS Contactors Wiring Manual 01518 53 000 Issue 2 13 January 2020 LASERMET WIRING CONTACTORS TO AN ICS 5 OR ICS 6 WIRING MANUAL Issue 2 ...

Page 2: ...ctors Wiring Manual 01518 53 000 Page 2 of 8 Issue 2 13 January 2020 LASERMET ICS Contactors Wiring Manual Contents 1 Safety Warnings 3 2 Concept 4 3 Testing 6 4 Specifications 7 5 Warranty 7 6 Contact Details 8 ...

Page 3: ...to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imperative that ...

Page 4: ... protection against the dangerous failure of a single contactor The contactor box needs to be wired to the line and load cables to be switched and the box may conveniently be located near these All wiring to the contactor main terminals must be made using wire of current and voltage rating appropriate to the power to be carried Overcurrent protection devices must be provided on the supply side of ...

Page 5: ...rlock equipment including control systems interlock switches illuminated warning signs laser shutters door locks external power supplies etc which can be connected to provide a complete laser interlock system Full support design and installation is available from Lasermet please contact us for any queries Contact details are given at the end of this manual ...

Page 6: ...oltage on the output load terminals of the contactors or on any outlet sockets or at the controlled device e g laser supply input terminals Press the Arm Laser button on the ICS and confirm the Laser Armed indication is lit Verify that both contactors are energised and that the correct voltage is present on all controlled socket outlets and or load equipment supply terminals Disarm the ICS by open...

Page 7: ...es and are not guaranteed Lasermet reserve the right to alter any specification without prior notice 5 Warranty Lasermet provide a 12 month warranty for defects in materials and manufacture from the date of installation or delivery Installations completed by Lasermet are covered against defects in workmanship for 12 months Damage or defects caused by other factors are not covered For example indus...

Page 8: ...vide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website www lasermet...

Reviews: