ICS-7-OEM Instruction Manual
02058-53-000
Page 6 of 29
Issue 3 19 January 2021
The ICS-7-OEM can accommodate expansion modules externally, and Lasermet offer a range of
modules including:
Uncommitted Relays
Active Guarding
Safety Logic Plus
Network Interface
Lasermet provides a full range of equipment including interlock switches, illuminated warning signs,
laser shutters, entry keypads with built-in fail-safe override timer, door locks, external power
supplies etc. which can be connected to the ICS-7-OEM to provide a complete system. Full support,
design and installation is available from Lasermet, please contact us for any queries. Contact details
are given at the end of this manual.
3.1 Differences between ICS-7-OEM and ICS-6-OEM
Power supply to expansion modules is now switched on in the disarmed state,
allowing visual checking of Active Guarding status before arming is attempted
An extra normally closed interlock output has been added in addition to the 7
normally open outputs
Fuses and option switches are now accessible without removing the top cover
Electronic over-current trips are used instead of fuses for the A and B
interlock supplies
The case has been expanded to allow single rows of 5mm terminals
An input/button has been added to reset faults latched on the Active Guarding
expansion module
An output has been added to indicate a fault on the expansion interface.
All inputs and output connections are now in ABBA format