PLMNL0286 REV. B, Effective Date: 06/06/19
22
FiberMINI
®
with Auto Focus (AF) Operation Manual
3.6 Control Box Indicator Lights
The control box has (5) indicator lights.
See
. It uses the discrete I/O
control box (PLCSA0081) as an example.
The indicator light labeled POWER
illuminates in green when power is
supplied to the control box.
The indicator light labeled READY
illuminates in green when the READY
output is active. The light illuminates
in red when a temperature fault is
detected within the head.
The indicator light labeled TOUCH
illuminates in green when the tip is in
contact with the part or another
conductive surface.
The indicator light labeled IN-
POSITION illuminates in green when
the lens is located at the target
position. The light illuminates in red
when the servo is shut off due to a
position fault, sending the lens to the
fully retracted position.
The indicator light labeled STATUS
illuminates in green when serial
communication is established with the
head. The light illuminates in red when
communication is lost.
Figure 21