Technical data
(Subject to technical alterations. 18W09)
Function
Range
Resolution
Accuracy
% of measured value (rdg)
+ least significant digits
AC current
Bandwidth: 50-400 Hz
600.0 μA
0.1 μA
± (1,0% rdg ± 3 digits)
6000 μA
1 μA
60.00 mA
10 μA
600.0 mA
0.1 mA
10.00 A
10 mA
± (2,0% rdg ± 8 digits)
DC current
600.0 μA
0.1 μA
± (1,0% rdg ± 3 digits)
6000 μA
1 μA
60.00 mA
10 μA
600.0 mA
0.1 mA
10.00 A
10 mA
± (1,5% rdg ± 3 digits)
AC voltage
Bandwidth: 50-1000 Hz
6.000 V
1 mV
± (1,0% rdg ± 5 digits)
60.00 V
10 mV
600.0 V
0.1 V
1000 V
1 V
± (1,2% rdg ± 5 digits)
Frequency
Accuracy: ± (1,0% rdg ± 5 digits)
Sensitivity: > 15 V RMS
Tastgrad
Accuracy: 5% … 95% ± (1,5% rdg ± 10 digits)
Sensitivity: > 15 V RMS