MultiMeter-Pocket
17
EN
Subject to technical alterations. 18W39
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ADX
Technical data
Function
Range
Precision
DC voltage
200 mV
± (0.5% rdg + 3 digits)
2.000 V, 20.00 V, 200.0 V
600 V
± (1.2% rdg + 3 digits)
AC voltage 40 - 400 Hz
2.000 V, 20.00 V
± (1.0% rdg + 8 digits)
200.0 V, 600 V
± (2.3% rdg + 10 digits)
DC current
200.0
A, 2000
A
± (2.0% rdg + 8 digits)
20.00 mA, 200.0 mA
AC current
200.0
A, 2000
A
± (2.5% rdg + 10 digits)
20.00 mA, 200.0 mA
Resistance
ą
± (0.8% rdg + 5 digits)
JąJąJą
± (1.2% rdg + 5 digits)
,ą
± (5.0% rdg + 5 digits)
,ą
± (10.0% rdg + 5 digits)
Max. input voltage
600 V AC/DC
Diode test
Test current 1 mA max., open circuit voltage of 1.5 V typical
Continuity test
TCHAKDRHFM@KHESGDQDRHRS@MBDHRą
Input resistance
,ą5#"5 "
Polarity
Sign for negative polarity
LCD
Up to 1999 (3.5 segments)
Fuse
mA,
A range: 0.2 A/500 V
Overvoltage
CAT III - 1000 V
Pollution degree
2
Degree of protection
IP 64
Operating conditions
-10°C ... 55°C, Max. humidity 80% rH, no condensation,
max. altitude 2000 m
Storage conditions
-10°C ... 60°C, Max. humidity 80% rH
Power supply
2 x 1.5 V AAA (NEDA24A/IEC LR 03)
Dimensions
120 x 55 x 40 mm
Weight
145 g
Test standards
EN 61326, EN 61010-1, EN 61010-2-031
Summary of Contents for MultiMeter-Pocket
Page 2: ...02...