MasterCross-Laser 2 / MasterCross-Laser 2G
11
B
C
2,5 m
<
1 mm = OK
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line.
The precision is within the specified tolerance if the deviation between the laser line and the plumb line
is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and switch on the cross laser. Mark
point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark
point C. Check whether the horizontal line from point C is level with point B
to within ± 1 mm. Repeat the process by turning the laser to the left.
Regularly check the adjustment before use, after transport and after extended periods of storage.
!
Technical data
(Subject to technical alterations 02.16)
Self-levelling range
± 3°
Precision
± 2 mm / 10 m
Laser wavelength linelaser (red)
635 nm
Laser wavelength linelaser (green)
510 nm
Laser class
2 / < 1 mW
Power supply
4 x 1.5 V alkaline batteries (Type AA) / battery
Operating time 2 / 2G
approx. 15 hours / approx. 4 hours
Operating temperature
0°C ... + 50°C
Storage temperature
-10°C ... + 70°C
Weight (incl. batteries)
570 g
Dimensions (W x H x D)
66 x 100 x 125 mm
EU directives and disposal
This device complies with all necessary standards for the free movement
of goods within the EU.
This product is an electric device and must be collected separately for disposal
according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info