LaserRangeMaster Pocket
09
b
e
d
c
f
a
1.
3.
7.
2.
8.
5.
4.
6.
GB
KEYPAD:
1.
2.
3.
4.
5.
6.
7.
8.
Measure / Continuous measurement
min / max continuous measurement
length, area, volume, Pythagoras
Unit of measure m/mm/ft/inch
ON/OFF
Measurement point (reference)
rear / tripod / front / pin
addition / subtraction of
lengths, areas, volumes
delete last measurement values
DISPLAY:
a
b
c
d
e
f
Measurement point (reference)
rear / tripod / front / pin
Display length, area / volume /
Pythagoras 1 / Pythagoras 2
Measurement values /
Measurement results
Unit m/mm/ft/inch
Intermediate values / min/max values
Battery symbol
min / max measurement
Important notices:
•
Caution:
Do not look directly into the beam. Lasers must be kept out
of reach of children. Never intentionally aim the device at people.
• The laser points to the location that will be measured. No objects may
get into the laser‘s line of measurement.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• The device is only conditionally useable in outdoor areas and cannot be
used in strong sunlight.
• The device cannot be used in strong sunlight.
• The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
• In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
• Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
• Measurements made through glass (window panes) can falsify mea-
surement results.
• An energy-saving function switches the device off automatically.
• Clean with a soft cloth. Water may not be allowed to penetrate the
housing.
Continuous measurement:
Use the ON/OFF button (5) to turn the
device on and press the READ button (1) for about 4 seconds. The device
now measures continuously and displays the smallest value (min), the
largest value (max) and the current value. Another brief press of the READ