Error codes:
Err101:
Err104:
Err152:
Err153:
Err154:
Err155:
Err156:
Err157:
Err160:
Replace the battery
Calculation error
Temperature is too high: > 40°C
Temperature is too low: < 0°C
Outside the measuring range
Received signal too weak
Received signal too strong
Incorrect measurement or background is too bright
The device is moving too much to measure.
Technical Data
(Subject to technical changes without notice)
Inside measurement range
0,1 m - 25 m
Precision (typical)*
± 3 mm / 10 m
Laser class
2 < 1 mW
Laser wavelength
650 nm
Power supply
2 x AAA 1.5 Volt batteries
Dimensions (W x H x D)
43 x 110 x 27 mm
Weight (incl. batteries)
100 g
Automatic switch-off
30
sec laser
/ 3
min device
Operating temperature
-10°C – 40°C
Storage temperature
-20°C – 70°C
* measuring distance up to 10 m with strongly reflective target surface and at room temperature.
The measurement deviation may increase by +/-0.2 mm/m for weakly reflective target surfaces.
Summary of Contents for DistanceMaster Compact
Page 2: ...02 Laser 2 x Typ AAA LR03 1 5V Alkaline...
Page 3: ...DistanceMaster Compact 03 x y m2 x y x y z x y z m3...
Page 56: ...56 b d c a e f g h i 1 2 4 3 2 1 650 EN 60825 1 2007 10 1 2 3 4 _ _ a b c d e f g h i _ _ l RU...
Page 58: ...58 1x 2x 3 sec 1x 2x 6x 4x 3x 5x 1 2 3 3 3 RU 3 sec...
Page 60: ...60 b d c a e f g h i 1 2 4 3 2 1 650 EN 60825 1 2007 10 1 2 3 4 _ _ a b c d e f g h i _ _ UA...
Page 62: ...62 1x 2x 3 sec 1x 2x 6x 4x 3x 5x 1 2 3 3 max min 3 UA 3 sec...
Page 86: ...86 1x 2x 3 sec 1x 2x 6x 4x 3x 5x 1 2 3 3 LC 3 BG 3 sec...
Page 90: ...90 1x 2x 3 sec 1x 2x 6x 4x 3x 5x 1 M 2 M 3 M 3 sec LC 3 mm GR 3 sec...